Safety Precautions On Servicing

12

Checks to electrical devices

Repair and maintenance to electrical components shall include initial safety checks and

 

component 

inspection procedures. If a fault exists that could compromise safety, then no

 

electrical supply shall be 

connected to the circuit until it is satisfactorily dealt with. If the fault

 

cannot be corrected immediately but 

it is necessary to continue operation, an adequate temporary solution shall be used. This shall be 

reported to the owner of the equipment so all

 

parties are advised.

Initial safety checks shall include:

-those capacitors are discharged: this shall be done in a safe manner to avoid possibility of

 

sparking;

-that there no live electrical components and wiring are exposed while charging, recovering

 

or purging 

the system;

-that there is continuity of earth bonding.

Releasing refrigerant into atmosphere is strictly forbidden!

Checks to the refrigeration equipment

Where electrical components are being changed, they shall be fit for the purpose and to the correct 

specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in 

doubt consult the manufacturer’s technical department for assistance.

The following checks shall be applied to installations using flammable refrigerants:

– The charge size is in accordance with the room size within which the refrigerant containing parts are 

installed;

– The ventilation machinery and outlets are operating adequately and are not obstructed;

– If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for

 

the presence 

of refrigerant;

– Marking to the equipment continues to be visible and legible. Markings and signs that are

 

illegible 

shall be corrected;

– refrigeration pipe or components are installed in a position where they are unlikely to be

 

exposed to 

any substance which may corrode refrigerant containing components, unless

 

the components are 

constructed of materials which are inherently resistant to being

 

corroded or are suitably protected 

against being so corroded.

Содержание DF 4123

Страница 1: ...Thank you for choosing this product Please read this instruction manual before using it DEHUMIDIFIER User Manual DYD T23A431 ...

Страница 2: ... If refrigerant leaks and comes in contact with fire or heating part it will create harmful gas and there is risk of fire Recycle unwanted materials instead of disposing of them All appliances and packaging should be sorted and tendered at a regional recycling centre and be processed in an ecological manner Further information is available in the USER MANUAL SERVICE MANUAL and the like ...

Страница 3: ...Figure1 Figure2 1 2 3 4 5 8 7 6 10 11 13 16 18 20 14 15 17 19 24 25 26 27 28 29 30 22 21 12 Figure3 31 32 1h 2h 4h 6h 8h 23 9 ...

Страница 4: ...ators 22 Time Indicators 23 Child Lock Indicator 24 Up And Down Buttons 25 Anion Button 26 Auto Button 27 Mode Button 28 Fan Speed Button 29 Timer Off Button 30 Power Button Components Control Panel Drainage 1 Handle 2 Air Inlet Grille 3 Drainage Outlet 4 Power Cord Bracket 5 Castors 6 Air Outlet 7 Rear Cover 8 Water Tank 10 Control Panel 11 Front Cover 9 Power Cord 31 Drainage Outlet Plug 32 Drai...

Страница 5: ...Product Instructions 1 Safety Instructions 1 2 Prior to Operation 3 Continuous Drainage 3 Operation Instructions 4 8 Cleaning 9 Storage 10 10 Safety Precautions On Servicing 11 12 13 Display Error Codes Trouble Shooting ...

Страница 6: ...T TO SERVICE Do not discharge the refrigerant into the atmosphere R 290 propane is flammable and heavier than air It collects first in low areas but can be circulated by the fans If propane gas is present or even suspected do not allow untrained personnel to attempt to find the cause The propane gas used in the unit has no odor The lack of smell does not indicate a lack of escaped gas If a leak is...

Страница 7: ... be stored in a well ventilated area where the room size corresponds to the room area as specified for operation Warning Failure to abide by this warning could result in an explosion death injury and property damage Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authori...

Страница 8: ...ed Ensure the tank is correctly fitted if the tank is full or not in place the tank full light comes on and the dehumidifier will stop working Continuous Drainage In general water will be collected by tank if you want continuous drainage please do steps as follows refer to figure 3 1 Unplug the drainage outlet plug 2 Insert the drainage pipe with 14mm inner diameter into water outlet Please always...

Страница 9: ...8h cancel for automatic shutoff by each press Auto timer off setting will be canceled if press timer button for 2 times in 3 seconds Auto timer off setting will be canceled if switch off the unit and switch on again Fan Speed Option Fan Speed button Press the fan speed button to select your preferred fan speed setting of low medium and high to meet the different usage requirements Fan speed button...

Страница 10: ...esh up the air quality Auto Dehumidifying Function Auto button Press the auto button to select the auto dehumidifying mode the unit runs automatically accordance to the ambient humidity detected below Ambient RH detected RH 65 55 RH 65 RH 55 Compressor Woking Woking Stop working Fan Speed Level High Medium Low Fan speed button and up down buttons are invalid Operation Instructions 1h 2h 4h 6h 8h 1...

Страница 11: ...runs with high fan speed without dehumidifying Fan speed button is valid Sleep Mode Press the mode button 3 times to select Sleep mode the unit runs with a designated humidity setting of 55 along with low fan speed All indicators will be off 5s after the setting is completed Touch any button to activate the light and to operate as usual Fan speed button is valid With no further operation after act...

Страница 12: ...s too low dehumidifier will enter into the defrost mode the unit runs with high fan speed without dehumidifying Fan speed button is invalid Safety Childlock Function Fan Speed button 2 seconds Low Temperature Defrost Mode 1h 2h 4h 6h 8h 1h 2h 4h 6h 8h Press the mode button 4 times to select Manual mode the unit runs by default continuous dehumidifying with medium fan speed At manual mode all butto...

Страница 13: ...mer setting will be canceled c Switch off the device and unplug the power cord then reconnect the power supply and switch on the dehumidifier It will run as factory preset mode the first time you received the dehumidifier Operation Instructions The unit will go into standby mode when water tank is full After emptying the tank the unit will go on or the water tank is not installed properly or insta...

Страница 14: ...he plug from the socket before cleaning 2 Clean the housing with soft dry cloth If the device is extremely dirty use a mild cleaning agent Wipe the dehumidifier with a slightly damp cloth Never spray the device with water 3 Remove the filter clean the filter with a vacuum cleaner or soapy water no hotter than 40 4 Rinse and dry the filter completely before installing back to the device Cleaning ...

Страница 15: ...of plastic Storage Please contact local distributor if any of the error codes below appears Display Error Codes E1 Temperature sensor error Humidity sensor error Flash every 30 seconds Flash every 30 seconds Machine works normally Machine works normally but can t set the humidity Display Code Error Display What is happening Air inlet temperature is too high 42ºC Slowly flash L3 Slowly flash L4 Com...

Страница 16: ... to be surveyed to make sure that there are no flammable hazards or ignition risks No Smoking signs shall be displayed Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work A degree of ventilation shall continue during the period that the work is carried out The ventilation should safely disperse any relea...

Страница 17: ...quipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to installations using flammable refrigerants The charge size is in accordance w...

Страница 18: ...ed Clean the air filter Set humidity is higher than the ambient humidity Set the humidity lower than ambient humidity Dehumidifier is blowing out warm air This is normal a dehumidifier is not an air cooler The device works but reduces the relative humidity insufficiently The dried air is passed over heating coils before it is blown into the room as part of the dehumidifying process The display is ...

Страница 19: ......

Отзывы: