background image

 3145 

 2110 

 83.07 

 123.82 

MEASURE THE WIDTH 

AND DEPTH

OF THE SHELTER TO 

CHECK 

CORRECT 

ALIGNMENT.

Please note 25mm Tec Screws 

are for roof panels only

CB1

JF1

S1C

CB1

CB1

CB1

Ensure correct corner 

alignment 

Step 1

 

Assemble 

S1C

 frames to make up the main structure using 

CB1

 brackets 

for the Corners and 

JF1

 brackets for the straight joints.

4

BLUE DIMENSIONS - MM

GREEN DIMENSIONS - INCH

Содержание NSSR1558F

Страница 1: ...Assembly Instructions Shelter type SR1562 F SR1562 F 05 200219 USA ...

Страница 2: ...1 2 3 4 10 12 13 14 12 11 5 9 6 8 7 15 2 Exploded View of Shelter Tools required Drill Screwdriver Mallet Hack saw Wrench Torx bit ...

Страница 3: ...Bracket 109x100x80 4 29x3 94x3 15 7 9 RB1 Bracket 110x42x40 4 33x1 81 12 10 R2 Rafter 2200x40x40 86 61x1 58x1 58 4 11 SS Sealing Strip Trim To 2200 Trim To 86 6 3 ROLLS 12 ACE2 Roof Panel 2210 x 1050 87 x 41 34 2 13 ACC2 Roof Panel 2210 x1030 87 x 40 55 1 14 RC2 Roof Strip 2180 85 83 4 15 A2 Roof Angle 1035 x 50 x 50 40 55 x 1 97 x 1 97 6 16 EC40 Plastic End Cap 40x40 1 58x1 58 20 Fittings Bolt se...

Страница 4: ...MENT Please note 25mm Tec Screws are for roof panels only CB1 JF1 S1C CB1 CB1 CB1 Ensure correct corner alignment Step 1 Assemble S1C frames to make up the main structure using CB1 brackets for the Corners and JF1 brackets for the straight joints 4 BLUE DIMENSIONS MM GREEN DIMENSIONS INCH ...

Страница 5: ... post using a JF1 bracket then use two JF1 brackets to attach S3C frame The ST5 tie bar is mounted using a CB1 and a JF1 bracket Make sure the structure is square then move the shelter to its final location before using the FT1 foot brackets to secure it to the ground 5 ...

Страница 6: ...R2 RB1 ENSURE CORRECT ALIGNMENT OF RAFTERS 995 39 17 1035 1035 1035 40 748 40 748 40 748 SCALE 1 20 Step 3 Attach R2 rafters using RB1 brackets 6 ...

Страница 7: ...ACE2 ACC2 ACE2 SS ACE2 ACE2 ACC2 SS Step 4 Stick sealing strips SS to the rafters Align the ACE2 roof panels with the outer roof rafters and equaly space the ACC2 panel in the middle 7 ...

Страница 8: ...A2 RC2 A2 RC2 Step 5 Screw down the RC2 directly into the rafter strips as shown below using 25mm Tech screws Screw the A2 Angle onto the edges of the roof as shown below 8 ...

Страница 9: ...35 1044 50 1035 1084 50 477 1531 50 995 1035 3145 OR 123 82 39 17 40 75 60 30 18 78 42 70 41 12 40 75 40 75 40 75 41 12 11 PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base 200mm OR 7 87in oversized on all 4 sides ...

Страница 10: ...Notes 9 ...

Страница 11: ...Notes 10 ...

Страница 12: ...panels regularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales nobutts com Web www nobutts com Tel 1 888 662 8887 No Butts Bin Company Inc 16 Birch Lane Madison CT 06443 All Parts and Fixings checked by Print Name Signature ...

Отзывы: