1.
ON/OFF Switch
This ON/OFF switch controls power to all of the
outlets on the UPS.
2.
AC Normal / On Battery / Boost Mode LED
(Green)
Indicate the utility power is normal / UPS on battery
or boost mode (flashing).
3.
UPS Abnormal LED (Red)
Indicate the UPS output overload / UPS charger
Failure / Replace Battery.
4.
Battery Power & Surge Protection Outlets
The three outlets not only provide full time surge
protection but also provide emergency battery
backup power during the utility power failure such
as a blackout or brownout.
5.
Surge Protection Outlets
The three outlets provide full time protection from
surge and spike.
Plug your peripheral equipments that do not
require power during the utility power failure.
Such as printers, scanners, fax machines, or
speakers.
6.
Coaxial Surge Protection
Provide protection for cable / satellite inputs.
7.
USB Port
Built-in USB port connects to your computer.
Provide the automatic shutdown with software
with USB cable to automatically save the files and
shut down the equipments if the utility power is
failure. Your personal computer can receive the
status as utility power line, utility power failure, on
battery and low battery by contact closure signals
that are sent through the USB port.
NOTE:
This connection is optional; your UPS will operate
normally without this connection
.
8.
Outlet protection for network / internet
The RJ45 jacks can provide protection against
surge and spikes on your internet line.
9.
Power Cord
Connect to the input utility power through the
power cord.
10.
Input Circuit Breaker
Protect against overload.
11.
Battery Replacement cover
Slide the cover off you can replace the battery.
Please refer to the following steps to replace the
battery.
a. Lay down the UPS and use the screwdriver to
open the battery cover on the bottom of the UPS.
b. Grasp the tab attached to the battery and slide
the battery out.
12.
Walls Mount Holes
Use the wall mount holes that you can mount UPS
to the wall.
Audible / Visual Indicators
Alarms
UPS
Status
ON
X
X
X
X
X
AC Mode
X
Blink
X
X
X
X
Boost
Mode
X
X
ON
X
X
Constant
ON
UPS /
Battery
fault
X
X
X
Blink
X
1 Beep at
4 sec
DC Mode
X
X
X
X
Blink
Beep
Intermitte
ntly*
Overload
*AC Mode
2 beeps at 1 second for 105% and 2 beeps @ 0.5 seconds for
130%. After 2 minutes, UPS will shutdown automatically.
*DC Mode
2 beeps at 1 second for 105%. After 20 seconds, UPS will
shutdown automatically. Or, immediately shutdown for 130
Verification Instructions
Once you have received the UPS product, you should
remove and inspect the product for shipping damage. If any
damage is found, please notify the carrier and your dealer.
You have to keep the shipping carton and the packing foam
in case the product must be
returned to the factory for service.
SAFETY INSTRUCTIONS
1.
Place the UPS indoors in an area that has adequate
airflow and is free excessive dust. Do
NOT
allow the
UPS to be exposed to moisture, rain, excessive heat or
direct sunlight.
2.
Use of the UPS product in life support applications
where failure of this equipment can reasonably be
expected to cause failure of life support equipment or