Nixie Temp n Glow IN-16 Скачать руководство пользователя страница 14

Temp’n’Glow IN‐16 Nixie Thermometer    Documentation 

 

 

 

14

 

14  Mounting the temperature sensors 

 
You can connect one or two sensors to your board. 

The temperature sensor (IC6 on the board) should not be soldered because the temperature is higher in 

he immediate vicinity of the board than the room temperature and thus the temperature would be 

t
incorrect. This component position is only for testing purposes. 

readings.  

 

lways connect the temperature sensors using shielded cable to the board for accurate 

nsor and a plug connected. 

A

With your kit you get a readymade cable (1 meter) with a se

 
The cable(s) are connected to the terminals X1 and (or) X2.  

ou can also make a cable yourself. Please do that according to a special documentation that is available 

or download from our website. 

Y
f

 

15  Maximum length of sensor cables 

The thermometer is designed for a maximum cable length of 10 meters.  
Please only use the cables from the shop. Otherwise you might get disturbances in the capacity of the 

cable data transfer.  

or short cables (1 meter), you can use your own 2 pin, fully shielded cable. But we recommend the cable 

rom our web shop. 

F

f

 

16  Connecting the thermometer to power 

All necessary settings can be made using the menu system. The thermometer 

must

 

be

 

mounted

 

in

 

a

 

housing

 so that the PCB and the components are protected against contact. 

 

nstall the 4 spacers as feet. Please check all solder joints closely. Plug in the power supply and 

do

 

not

 

I

touch

 

anything

 

on

 

the

 

board

 

(170

 

volts

 

DC).

 

 

The initialization should start now and the temperature (s) should appear. 

 
During power up the circuit needs about 2 seconds to initialize. During this time, the display shows an 

ndefinite number of values. Then the correct temperature is displayed. If not, refer to the error 

escription (chapter 3 of this documentation) 

i
d

 

The

 

thermometer

 

must

 

be

 

mounted

 

in

 

a

 

housing

 

so

 

that

 

the

 

PCB

 

and

 

the

 

components

 

are

 

protected

 

against

 

contact.

 

Содержание Temp n Glow IN-16

Страница 1: ...e art too A smart menu system makes operation easy Adjustable change interval error detection and many other features are standard on Temp n Glow A high to go light is the so called Cathode Poisoning...

Страница 2: ...6 Error indication 6 7 Special Notes on the IN 16 tubes 6 8 Part List 8 9 Soldering 9 10 Mounting of the Neon glow lamp 10 11 Solder the tubes 11 12 Solder the Leds 12 13 Switching off the underside L...

Страница 3: ...ject and liquid entry Care should be taken so that the thermometer does not fall into liquids them spilled over the thermometer Do not use this appliance for anything other than the intended use as de...

Страница 4: ...F no adjustment nece measuring range from 55 C to 85 C 67 F to 99 Display in C or F Long cables available for external sensor up to 10 m Pre assembled temperature sensor cable available from web shop...

Страница 5: ...equently ll settings are described A a 4 Settings 1 change interval reby the value of x is the range 1 9 in seconds nside outside or only one of them is updated at a range of 1 9 seconds The display s...

Страница 6: ...ure is below 99 or over 99 C or F the display still shows 99 to 99 6 Error indication If one of the sensor is not connected or produces a bad signal then 99 is di he left decimal point blinks left in...

Страница 7: ...e tubes holes in the spacer After you have drilled you need to connect the tube wires through the his can easily be done by a spiral staircase cut of the wires hen the threading into the spacer and th...

Страница 8: ...Temperature sensor with cable 1 meter L1 1 Coil 330 H 1 4 A R10 R11 2 Resistor 180 Ohm R20 1 Resistor 390 Ohm R30 R31 2 Resistor 2 2k R32 R33 2 Resistor 4 7k R38 1 Resistor 8 2k R40 R43 4 Resistor 16k...

Страница 9: ...tch ut for the marking that you find on the IC and on the pcb Then L1 the capacitors the resonator CR1 and he coil are soldered in The resonator has no polarity o t Figure 1 resistor and diodes mounte...

Страница 10: ...t g p 10 Mounting of the Neon glow lamp Cut fuse holder tab ts ter 1mm Cut the fuse holder contac ire diame Stretch silver w Solder wire from the rear Bend the wires Pull 2 pieces of shrinking tube 21...

Страница 11: ...be sure that the tube is soldered correctly into the board it is important to know where the anode is Figure 4 The step cut The anode is marked white and you find it at the back of the tube You can s...

Страница 12: ...oles hold wires after the tube has been mounted No hole is free lign the tubes rectangular You should first solder only two wires and check the angle Now solder the est of the wires and cut he rest no...

Страница 13: ...underside LED illumination The Leds illuminate the underside of the board creating a beautiful effect in a n acrylic enclosure at night f you do not want the effect you can easily switch that off With...

Страница 14: ...cable length of 10 meters Please only use the cables from the shop Otherwise you might get disturbances in the capacity of the cable data transfer or short cables 1 meter you can use your own 2 pin f...

Страница 15: ...A Maximum input voltage 14 V m Maximum input current at 12 V 150 12V 1 8 W Maximum input power at Measuring range 55 C to 99 C e of 10 C to 85 C Range 67 F to 99 F g Tolerance 0 5 C in the ran Overall...

Отзывы: