9.2.2.3 Device-specific settings
Operating
type
HOLD
Measurement: OFF, transmission: ON
RUN
Measurement: ON, transmission: ON
OFF
Measurement: OFF, transmission: OFF
OFFLINE
Measurement: ON, transmission: OFF
Aloha
Reserved for internal use
Accu type
Charging rule for the accu pack used (temp...charging conditions, V
low
... charge level)
Battery
Charge regulator deactivated
Li-ion
Temp.:0°C to +45°C, V
low
:3,7V
NiMH
Temp.:-10°C to +60°C, V
low
:3,9V
Solar
Temp.:0°C to +45°C, always charging
AP404D
Temp.:0°C to +45°C, V
low
:3,7V
AP404D solar
Temp.:0°C to +45°C, always charging
AP413D
Temp.:0°C to +45°C, V
low
:3,7V
AP413D solar
Temp.:0°C to +45°C, always charging
Temp.:-30°C to +60°C, V
low
:3,7V
solar Temp.:-30°C to +60°C, always charging
Temp.:-30°C to +60°C, V
low
:3,7V
solar Temp.:-30°C to +60°C, always charging
AP403D
Temp.:-40°C to +80°C, V
low
:3,7V
AP403D solar
Temp.:-40°C to +80°C, always charging
LiPo backup
Temp.:0°C to +45°C, V
low
:3,7V
BP434R
Charge regulator deactivated
9.2.2.4 GPRS
SIM tariff
Selected SIM tariff