3. INSTALLATION 

The device can be installed in several ways, depending on the design (vertical, horizontal, angle), with threaded connections, mounting plates, adapters, adjusting units, 
etc. The unit must be protected against steady material influx by selecting the appropriate mounting position or using an overhead protective shield. When the device is 
mounted onto the side of the tank, coning or arching of the material must be taken into consideration. The preferred location for the unit is the one with the least amount of 
vibration. It is important that the device is installed so that the cable glands are in the correct position. 
If the device is mounted onto the side of the tank, deposits may clog the connection point and block the movement of the paddle; therefore, they must be prevented.  
If a 3-blade unit is on a mounting plate, the insertion hole must be at least 

110 mm (4.3 inches) for the paddle to pass safely. Do not forget to use the mounting plate 

seal! When mounted on a bracket or mounting plate, a 1" or 1½" flat nut can be ordered to fasten the unit. Mounting plates thinner than 9 mm (0.35 inches) requires 
spacers. Attaching rod extensions longer than 0.5 m (20 inches) to the tank wall is recommended. For upper-level switching, using a standard model with the appropriate 
paddle between the process connection and the measured medium standard is recommended, and if necessary, it must be equipped with a flexible coupling or a rod 
extension to reach the required detection level. When using the unit for low fail-safe indication, it is necessary to install a deflector element. A cable-extended version 
recommended for low-level switching, with a suitably-sized rigid tube, if necessary. A rigid tube is recommended if the measured medium forms a steep cone or the 
surface is so rigid that the paddle cannot penetrate the material, and the level tends to deviate significantly from its vertical position. If so, it is recommended to use a rigid 
tube for proper operation.  
Besides, there are countless ways to use the device, but you should always be careful about choosing the right process connection and protection of the device. 
 

Protection with a protective shield 

 

Connection for mounting plate (recommended) 

 

 

 

 

Side mounting

 

 

Mounting

 

Correct  

 

 

Correct  

 

Incorrect 

 

Incorrect 

 

 

In case of side-mounted units, the cable glands should face down!

 
4. MOUNTING 

The paddle must be fixed to the device by inserting the two attached pins before 
the installation. When using a mounting plate, it must be mounted first, followed 
by the paddle. The cable of cable-extended units can be secured the same way 
as the pins.  
 
To customize the cable extension’s length, cut the cable starting from the lower 
end. First, remove the grub screws from the lower cable holder. Then cut the 
cable to the required length. It is recommended to wrap adhesive tape around 
the wires of the cable when cutting to prevent them from fanning out. After 
cutting the cable, the holder must be assembled with the probe. If a rigid tube is 
attached to the unit, it must be cut for the appropriate length before re-
assembling! 
 
Modifying the insertion length of an extended rod version is possible with the 
optional sliding sleeve. It needs a 1½" BSP / NPT nozzle. The BSPT thread can 
be screwed into a suitable BSP or an NPT threaded nozzle with a hex neck 
(SW55 size wrench for 1½"), and the single-blade paddle can be passed through 
the hole. 