7
side facing the Plate D by adjusting the Head, but
impossible on the upper side facing the Plate C. For
making a radius tangential line cutting on the upper
side, conduct in a following manner.
(1) Place the tool on workpiece with Plate C on upper
surface of workpiece and Plate D on side surface,
as indicated in Fig.9. Then, turn the Eccentric Ring
to adjust the Indexable Inserts to cut properly side
surface, and conduct the first cut. (see Fig.10)
(2) Next, placing Plate C onside surface and Plate D
on upper surface, conduct the second cut.
(3) In this case, slight seam may be left in center of
chamfered surface. (Fig.11)
Upper Surface
Side Surface
Plate C
Plate D
Fig.9
T
angential
Line
Side
First cut
Surface
Uppe Surface
R
Fig.10 Fig.11
5-9. How To operation the Dust Box
WARNING
●
Be sure to turn the switch OFF and remove the
power plug from power supply whenever setting
up the tool.
●
The Dust Box is much heated right after the
operation. Always wear gloves in handling the
Dust Box.
CAUTION
●
Frequently throw away the chips in the dust box
before pilling up. If the tool is operated with the
dust box filled with the chips, it badly affects
finishing surfaces shorten the life of Indexable
Insert.
Hold the motor firmly, and throw away the chips by
opening the lid. (Fig.12)
Chip
Fig.12
5-10. Restart Prevention Function
If the power is failed or the tool is accidentally
unplugged from the power supply while in operation,
the restart prevention function will be automatically
activated when the power is restored. The restart
prevention function will keep the motor of the tool
from running even if the power is recovered or you
put in the plug again.
To resume work, turn off the switch and then turn it
on once again.
5-11. Kick Back Stop
When a big shock is given to the cutter during
operation, the motor will stop automatically to protect
the operator and the tool.
Chamfering can only be resumed once the switch is
turned on again.
5-12. How To Chamfer Outer Diameter
WARNING
●
Be sure to turn the switch OFF and remove the
power plug from power supply whenever the
accessories are attached or removed.
The tool can be used on the workpieces at the
minimum diameter of 300mm by adjusting dimension
A of both Hex. Socket Set Screws (8
25 special)
①
in either direction. (Fig.13)
Remember that this operation requires the workpieces
of at least 12mm length. (Fig.14)
(1) In the case of constant R (Circle), install two Hex.
Socket Set Screws (8
25 special)
①
on Plate
D and tighten with Hex. Nuts. Make sure that the
dimension A of the left and the right screws are
equal.
Chamfering on an outer diameter of O.D. 200mm –
O.D. 300mm can done by placing the Hex. Nut on
the other side of Plate D. (Fig.13, 14)
(2) In the case of variable R (Oval), remove one of the
two Hex. Socket Set Screws (8
25 special)
①
.
Side
Second cut
Surface
Uppe Surface
Tangential
Line
T
angential
Line
R
R