![Nitto Seiko SH300 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/nitto-seiko/sh300/sh300_instruction-manual_1696678008.webp)
Rotary auxiliary hopper SH300
3
2.3. Connection
Connect “SH300” in the following procedure. (See
“1.2. Names of the parts”.)
(1) Check that the illuminated power switch (SW1) of the “SH300” is turned off.
(2) Connect the plug of the “Power cable with a plug” of the “SH300” to the 3P receptacle (CN SH) of the
Vibratory Track Screw Feeder “FF/FM503H”. (Refer to
the “Vibratory Track Screw Feeder
FF/FM503H Instruction Manual” as necessary.)
(CN SH)
(CN IO)
”
2.4. Power-on
Turn on the “SH300” in the following procedure. (Refer to
“l.2. Names of the parts” and “2.3.
Connection”.)
(1) First, check that the power to the “FF/FM503H” main unit is supplied and the power switch is turned
on. (For more information, refer to
“Vibratory Track Screw Feeder FF/FM503H-E Instruction
Manual”.)
(2) When the illuminated power switch (SW1) is turned on, the LED lights up and the hopper rotates.
(3) Adjust the detection point of the proximity switch to detect hopper stoppage as necessary. When this
proximity switch is turned on, the hopper stops.
3. Failure cause and corrective measure
The following describes the causes of and corrective measures against typical troubles.
Failure description
Possible cause
Corrective measure
H
op
per
does
not
r
ot
at
e.
The LED lights up
when the illuminated
power switch (SW1)
is turned on.
The toothed gear is not engaged.
Set the hopper at a proper
position.
Screws exceeding hopper capacity are put in.
Do not put in screws
exceeding specified amount.
Although the
illuminated power
switch is turned on,
the LED does not
light up.
At the side of
FF/FM503H
main unit
Power is not supplied.
Turn on the power to the
main unit.
Power switch is not turned on.
Turn on the power switch of
the main unit.
At the side of
SH300
The plug of the “Power cable with
a plug” is not inserted into the 3P
receptacle (CN SH) of the
“FF/FM503H” main unit correctly,
or the plug is connected to another
electric device.
Connect the plug of the
“Power cable with a plug” to
the 3P receptacle (CN SH)
of the “FF/FM503H” main
unit correctly.
Fuse is blown.
Replace the fuse.