KX driver tool unit
11
How to set parameter
Set parameters as follows:
(For more information on each parameter, refer to a separate document “Parameter list”.)
(Controller display example)
[11] After all the changes have been completed,
turn off the power. After
the indication on the display has been disappeared, turn on the
power again.
[1] Press key to move the cursor (blinking digit) to the upper most
digit.
[2] While holding down key, press key or key to change the
digit at cursor position to
“
L
”
.
[3] Press key to move the cursor to the next right digit.
[4] While holding down key, press key or key to change the
digit at cursor position to
“
P
”
.
(When you set parameters 100-199, press key and key at the
same time while holding down key to change the digit to
“
P.
”
.)
[5] Press key to move the cursor to the right, and press key to
change the number of a parameter that you want to set.
[6] Press key to move the cursor to the right most digit (4th digit).
[7] If key is pressed further, the setting value of current parameter is
displayed. Using , or key, change the value displayed.
[8] After the setting value of the parameter is changed, press key to
move the cursor to the upper most digit (
“
L
”
is displayed).
[9] Press and hold down key until the display changes to numeric
values.
(Previous display is restored if the key is released.)
[10] Writing the setting values to the flash memory is completed with the
steps above.
To change a setting value of another parameter, repeat the steps
from [4] to [9].
(Caution) The values shown on the controller display are for example only. So, actual values may be
different.