Nitrous Express MAXIMIZER-II Скачать руководство пользователя страница 12

10 

 

 

MAXIMIZER-II rev A

 

2

2

.

.

4

4

.

.

3

3

 

 

S

S

a

a

v

v

i

i

n

n

g

g

 

 

a

a

n

n

d

d

 

 

U

U

p

p

l

l

o

o

a

a

d

d

i

i

n

n

g

g

 

 

y

y

o

o

u

u

r

r

 

 

C

C

o

o

n

n

f

f

i

i

g

g

u

u

r

r

a

a

t

t

i

i

o

o

n

n

 

 

It is recommended that you save your configuration and log files in the directory  

 

C:\Program Files\NX MAXIMIZER-II II 

 
To save your configuration on the PC, click on 

File

 then 

Save As…

 

and enter a name for the configuration. It is possible to save multiple 
configurations on the PC, but only one config can be loaded into the 
MAXIMIZER-II. 
 
To upload a saved configuration to the MAXIMIZER-II, ensure the 

MAXIMIZER-II is turned on. Open the desired configuration and click on the UPLOAD button (green 
arrow pointing to car). 
 
To download a configuration from the MAXIMIZER-II, ensure the MAXIMIZER-II is turned on. Open a 
default configuration by clicking on 

File

 then 

New.

 Now click on the DOWNLOAD button (green arrow 

pointing from car). This will read the MAXIMIZER-II’s configuration into the current open configuration 
on the PC. 
 

2

2

.

.

5

5

 

 

M

M

o

o

n

n

i

i

t

t

o

o

r

r

 

 

a

a

n

n

d

d

 

 

D

D

a

a

t

t

a

a

 

 

L

L

o

o

g

g

g

g

i

i

n

n

g

g

 

 

 

 

To monitor and/or data log requires that a PC is 
connected to the MAXIMIZER-II.  

 

2

2

.

.

5

5

.

.

1

1

 

 

M

M

o

o

n

n

i

i

t

t

o

o

r

r

i

i

n

n

g

g

 

 

 

 

  
 
 
This screen graphically displays the operational 
status of the MAXIMIZER-II in real-time. To access 
this screen, simply click the Monitor button on the 
Main Screen or type M. 
 
To exit this screen click on the X in the upper right 
hand corner of the screen, toggle the monitor button 
or type M. 

 

 

Содержание MAXIMIZER-II

Страница 1: ...ing Caution EXTREME DANGER Caution Do not use or mix any other manufacturer s products with any Nitrous Express products Do not use or mix any Nitrous Express products with any other manufacturer s pr...

Страница 2: ...eneral Options Tab 4 2 3 2 Miscellaneous Option Tabs 4 2 4 MAXIMIZER II Configuration 5 2 4 1 General Tab 5 2 4 2 Stage 1 2 Tab 8 2 4 2 1 Time Based Nitrous Configuration 9 2 4 2 2 RPM Based Nitrous C...

Страница 3: ...RIVER must be connected to a good ground location that can handle 40 AMPS DO NOT connect to the ECU ground connection While pulsing the solenoids this will generate large amounts of electrical noise t...

Страница 4: ...10 0 B Bo ot tt tl le e H He ea at te er r E En na ab bl le e I In np pu ut t Grounding this input is considered the ENABLE position for the automatic bottle heater control This feature allows the MAX...

Страница 5: ...t te er ri in ng g U Us se er r D Da at ta a Drag Slide data fields that have this feature have a down arrow button to the right Clicking and holding the button causes a slider bar to appear Moving th...

Страница 6: ...the maximum retry count before the software displays a timeout error For most PC s this should be set to 3 Number of retries on CRC error sets the maximum retry count before the software displays a C...

Страница 7: ...fjoracing com Wideband AFR System Controller is recommended It will enable the MAXIMIZER II to accurately display and log your air fuel ratio RPM Signal Present allows you to select whether or not yo...

Страница 8: ...eature allows you to use the automatic bottle heater control as well as log your bottle pressure A check mark in the box tells the MAXIMIZER II that the sensor is connected and enables the automatic b...

Страница 9: ...ype allows you to select the type of transmission manual or automatic If Manual there is no more configuration required for Transmission If Automatic proceed as follows Detect Gearshift Above allows y...

Страница 10: ...AT and WOT is used to attenuate the nitrous ramp by as much as 35 TPS Trigger at allows you to set the throttle point above which the nitrous can be turned on EGO Cutoff allows you to set the lean poi...

Страница 11: ...to the desired settings or by using the methods described in the Entering User Data section Ramp allows you to set the time taken from the START of the Nitrous to the FINAL This can be set by draggin...

Страница 12: ...button green arrow pointing to car To download a configuration from the MAXIMIZER II ensure the MAXIMIZER II is turned on Open a default configuration by clicking on File then New Now click on the DOW...

Страница 13: ...Open In the Files of type section select MAXIMIZER II II Logs If the log files do not appear in your window you may not be in the correct directory To change directories click on the down arrow in the...

Страница 14: ...area to be zoomed To zoom out click on the Unzoom button that appears in the upper right when you zoom in Additional features are available to customize the graph view as well as export the screen to...

Страница 15: ...does not warrant equipment parts or components purchased by FJO or the customer from any third party manufacturers or suppliers Rather for any defect in respect of equipment parts and components purch...

Страница 16: ...14 MAXIMIZER II rev A 6 6 1 1 S Sy ys st te em m...

Страница 17: ...15 MAXIMIZER II rev A 6 6 2 2 S St ta at tu us s L LE ED D 6 6 3 3 1 12 2 v vo ol lt t A Ar rm mi in ng g S Sw wi it tc ch h...

Страница 18: ...16 MAXIMIZER II rev A 6 6 4 4 I Ig gn ni it ti io on n R Re et ta ar rd d 6 6 5 5 R Re em mo ot te e B Bo ot tt tl le e O Op pe en ne er r...

Страница 19: ...17 MAXIMIZER II rev A 6 6 6 6 A Au ut to om ma at ti ic c P Pu ur rg ge e 6 6 7 7 F Fu ue el l P Pr re es ss su ur re e S Sa af fe et ty y C Cu ut t o of ff f S Sw wi it tc ch h...

Страница 20: ...figuration to 4 5 volts the TPS TRIGGER to 95 and the IDLE to 0 5 volts Figure B illustrates how to connect a GROUND wide open throttle switch Set the WOT setting in the MAXIMIZER II configuration to...

Отзывы: