![Nitrous Express 15935 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/nitrous-express/15935/15935_operating-instructions_1696474001.webp)
Read all Instructions before
beginning!!!!
Caution – EXTREME DANGER – Caution
Do not use or mix any other manufacturer’s products with any Nitrous Express products.
Do not use or mix any Nitrous Express products with any other manufacturer’s products.
THESE INSTRUCTIONS APPLY TO NITROUS EXPRESS PRODUCTS ONLY!
FOR SANCTIONED RACE USE ONLY - NOT FOR SALE OR USE IN CALIFORNIA
NITROUS EXPRESS HOT WATER BOTTLE BATH INSTRUCTIONS
IMPORTANT!!!
NEVER PLUG IN OR TURN ON HEATER WITHOUT
WATER COVERING THE HEATING ELEMENT…IMMEDIATE DAMAGE WILL
OCCUR
Key Instructions:
1.
RST Button: (On/Off switch)
A.
If the unit does not turn on when plugged in, press the RST key once to turn the unit on.
B.
To Power off the unit simply unplug from the power source.
2.
SET Button:
A.
Press the SET key once to enter the temperature control setting, press up or down button to adjust the desired
water temperature then press the SET key again to exit setting mode.
B.
Press and hold SET key for three seconds to enter the system menu settings, press the up or down key to select
the adjustment menu, press set key once to enter the appropriate parameter settings, press up or down to
adjust parameters needed to be modified, once adjusted, press the RST key to exit.
Operating instructions
LED Status Description:
The HEAT light at the left side of the screen are used as the working indicator light, flashing is to indicate the delay of
heating, if the LED is on solid it indicates it is on the status of heating.
Possible Codes and the settings:
Code
Definition
Setting Range
Default
Unit
HC
Heating / Cooling
H, C, or HC
C
N/A
CP
Temp Hysteresis
1-30 Deg F
2
Fahrenheit
LA
Lower temp limit
-58 Deg F
-58 Deg F
Fahrenheit
HA
Upper temp limit
194 Deg F
194 Deg F
Fahrenheit
PU
Delayed start
0-10 minutes
2 minutes
Minutes
CA
Temp calibration
-10 to +10
0
Fahrenheit