- 18 -
5. Check After Installation
When you finish the installation of the entire system, check if it is
installed correctly before supplying power.
Check if locking device and other devices work normally as the
following order. For more information, please refer to "NAC-3000
Terminal User Manual" and "NAC-3000 Software User Manual".
①
When power is supplied, the initial screen with NITGEN logo will
appear.
②
Press the menu button to choose System Option > Terminal Mode
and check if the terminal is in SO mode.
③
Choose User Manager from the menu and then register user ID and
fingerprint. (By default, user ID is set to 4 digits long.)
④
Test the devices (including locking device) attached to the terminal
by performing fingerprint authentication.
⑤
If there's no problem, delete the fingerprint you registered for the
test.
If you manage terminals via the network after installation, proceed the
following test:
①
Install the program on a server PC for manager registration and
initial settings.
②
Set the terminal mode to NL or NS from the terminal menu.
③
Set the network environment from the terminal menu.
④
Run Remote Manager to check the terminal connection and then
register it.
⑤
In the server PC, register a terminal user and check if the
authentication is performed normally.
⑥
If there's no problem, delete both server and terminal users.