34

 

12F, Daemyung Valeon bldg., 127, Beobwon-ro, 
Songpa-gu, Seoul, Korea (05836) 
Tel : 02-6488-3232 , Fax : 02-6488-3099,   
E-Mail :[email protected] 

http://www.nitgen.com

 

 

NETWORK  NO USE 

Operate in single mode 

 

USE 

AUTH MODE   

Server/Terminal 
Terminal/Server 
Server 
Terminal 

TERMINAL ID 

TERMINAL ID 

STATIC 
DHCP 

STATIC 

IP 
Subnet mask 
Gateway 

DHCP 

 

SERVER 

SERVER 
Port No 

OPTION 

ATTEND 

TYPE 

NONE 
M1 F1~F2 
M2 F1~F4 
M3 F1~F49 

AUTO TNA 

NO 
YES 

SCREEN 

LANGUAGE 
ENGLISH(0) 
KOREAN(1) 
INDONESIAN(2) 
MULTILINGUAL(3) 
ARABIC(4) 
SPANISH(5) 
PORTUGUESE(6) 
FRENCH(7) 
RUSSIAN(8) 
FARSI(9) 
JAPANESE(10) 
CHINESE(11) 

 

SHOW ID 

NO 
YES 

USER LOGO 

NO USE 
USE 

USER ID LEN 

4~16 

SAVE 

LOG SAVE 

NO 
YES 

IMAGE SAVE 

NO 
YES 

TIMEOUT 

RESULT 

 

NET ERROR 

 

PING   

 

Date   

FORM 
 

YYMMDD 
DDMMYY 
MMDDYY 

Содержание eNBioAccess-T2

Страница 1: ...13 NITGEN Co Ltd All rights reserved It is strictly prohibited to compile duplicate or publish part Or whole of this manual prior written consent of NITGEN The specification of this product may be cha...

Страница 2: ...u Deletion 1000 04 1 30 2016 09 19 User Logo Description Addition Terminal LC015B Interface modification Added the some description for User Input in Backup Menu 1000 05 1 40 2016 09 29 Added the pict...

Страница 3: ...ne Authentication 1 N Identification The user is searched only by the fingerprint The same fingerprint as the input fingerprint is identified among the registered fingerprints without User ID or Card...

Страница 4: ...pe MCP040 18 2 2 4 Network Type Door Lock 19 2 2 5 Network Type Lock Controller 19 2 3 Product Specification 20 3 Environment Setting 21 3 1 Checkpoints before Environment Setting 21 3 1 1 Menu 21 3 1...

Страница 5: ...3 8 1 Menu configuration 48 3 8 2 ATTEND 48 3 8 3 Screen 50 3 8 4 SAVE 52 3 8 5 TIMEOUT 53 3 8 6 LOCKING 54 3 9 INT DEVICE 56 3 9 1 Menu Configuration 56 3 9 2 FP SENSOR 56 3 9 3 BEEP 58 3 9 4 VOICE 5...

Страница 6: ...osed to direct sunlight Otherwise it may cause malfunction deformation and discoloration Do not install the terminal in humid or dusty places Otherwise it may cause malfunction Do not clean this termi...

Страница 7: ...a gu Seoul Korea 05836 Tel 02 6488 3232 Fax 02 6488 3099 E Mail customer nitgen com http www nitgen com 1 2 Product Details 1 2 1 FRONT Camera LCD Function KEY F1 F4 Speaker Card Sensor EM SC HID Fing...

Страница 8: ...ess T2 User Guide 8 12F Daemyung Valeon bldg 127 Beobwon ro Songpa gu Seoul Korea 05836 Tel 02 6488 3232 Fax 02 6488 3099 E Mail customer nitgen com http www nitgen com 1 2 2 REAR Fixed bracket Cable...

Страница 9: ...s T2 User Guide 9 12F Daemyung Valeon bldg 127 Beobwon ro Songpa gu Seoul Korea 05836 Tel 02 6488 3232 Fax 02 6488 3099 E Mail customer nitgen com http www nitgen com 1 2 3 Input Output 1 2 3 1 Cable...

Страница 10: ...T1 OUT Output WIGAND WO1 12 BROWN WI0 WIE_IN0 IN Input WIGAND WI0 13 PURPLE WI1 WIE_IN1 IN Input WIGAND WI1 14 BLACK GND GND Ground connection WIGAND signal 15 RED N_TXN OUT LAN I F LAN cable 16 BLACK...

Страница 11: ...n INSIDE OPEN IN0 DC12V LC015B separate power supply DC12V IN ground connection Power only for LC015B GND But door open time can be set with DIP SWITCH of LC015B Maximum open time is 5 sec 1 2 3 5 Ter...

Страница 12: ...d Connected with server Gate State Gate is closed Gate is opened Gate is opened forcedly unusual door open state Gate communication problem Warning signal State NONE Normal Terminal Disassembly State...

Страница 13: ...anation UP F1 Move cursor up DOWN F3 Move cursor down LEFT F2 Move cursor to left ESC F2 long Move to upper menu RIGHT F4 Move cursor to right ENTER F4 long or F4 Move to submenu ENABLE DISABLE F2 Cat...

Страница 14: ...Songpa gu Seoul Korea 05836 Tel 02 6488 3232 Fax 02 6488 3099 E Mail customer nitgen com http www nitgen com Menu of Initial Screen Authentication succeess Authentication failure Waiting for Card Inp...

Страница 15: ...ays ON Touch in initial screen ON Maintain for 10 seconds OFF 1 5 Voice information during operation Category Voice information Fingerprint Input Please enter your fingerprint Authentication success Y...

Страница 16: ...rints are difficult to recognize In this case the fingerprint of another finger should be registered Precautions subject to your fingerprint state The availability of the fingerprint may vary subject...

Страница 17: ...se of personal fingerprints enhances the security of authentication Access control system using the local area network LAN The fingerprint reader communicates with the authentication server using a TC...

Страница 18: ...nitgen com http www nitgen com 2 2 Diagram 2 2 1 Single Type Door Lock 2 2 2 Single Type Lock Controller 2 2 3 Dummy Type MCP040 Door Lock Lock control BLE 2 4G Mobile App T2 Close Open Lock Controll...

Страница 19: ...02 6488 3099 E Mail customer nitgen com http www nitgen com 2 2 4 Network Type Door Lock 2 2 5 Network Type Lock Controller Lock Control BLE 2 4G Mobile App Close Ethernet Open T2 Door Lock Ethernet...

Страница 20: ...Optical 500 DPI Authentication Method Fingerprint RF Card Mobile Card Authentication Speed 1 N within1sec based on 1 000 fingerprints Fingerprint capacity 20 000 Fingerprints 10 000 users Two identic...

Страница 21: ...ter when shipping the product 3 1 2 Administration authentication When the administrator is registered the admin authentication screen is displayed at first as follows Administrator authentication Adm...

Страница 22: ...dministrator Power terminal OFF Disassemble device and make case open state While case opens make DIP of rear side switch ON state as follows Power terminal ON After the terminal completely booted Pre...

Страница 23: ...MENU OPTION SAVE IMAGE SAVE No MENU OPTION TIME OUT RESULT 1sec MENU OPTION TIME OUT NET ERROR 30sec MENU OPTION TIME OUT PING 60sec MENU OPTION LOCKING NO USE MENU INT DEVICE FP SENSOR 1 1 LEVEL 5 M...

Страница 24: ...setting MENU NETWORK NO USE MENU EXT DEVICE DOORLOCK LOCK1 TYPE MOTOR1 MENU EXT DEVICE DOORLOCK DM0 N O or N C MENU EXT DEVICE DOORLOCK LOCK2 TYPE MOTOR2 MENU EXT DEVICE DOORLOCK DM1 N O or N C MENU E...

Страница 25: ...NETWORK USE TERMINAL STATIC IP 192 168 0 3 SN 255 255 255 0 GW 192 168 0 1 MENU NETWORK USE SERVER IP 192 168 0 2 PORT 7332 MENU EXT DEVICE DOORLOCK LOCK1 TYPE STRIKE OK MENU EXT DEVICE DOORLOCK DM0 N...

Страница 26: ...OCK DM0 NONE MENU EXT DEVICE DOORLOCK LOCK2 TYPE NONE MENU EXT DEVICE DOORLOCK DM1 NONE MENU EXT DEVICE RS485 TYPE LC010 MENU EXT DEVICE RS485 DEV ID 0 3 1 6 9 Network Type Lock Controller LC015 Menu...

Страница 27: ...r the terminal in Admin App 3 2 1 Install iAccess M Plus iAccess M Plus is the smartphone App for administrator controlling device via BLE You can download and install it from Play Store For more deta...

Страница 28: ...istrator s ID password and click OK in empty state 3 2 5 Administrator authentication of the terminal If an administrator is registered in the terminal it requires to input card or fingerprint for adm...

Страница 29: ...ministrator is registered in the terminal it requires the administrator authentication If there is no administrator the login succeeds immediately If the login is successful you receive the list of us...

Страница 30: ...tion between ACM Pro and terminal 3 4 1 Install ACM Pro When shipping the product it installs ACM Pro Program in PC from the provided CD For installation guide please refer the relevant document 3 4 2...

Страница 31: ...mation Move to MENU NETWORK USE TERMINAL and check whether lower information is correct or not If you have not changed the device network information it is displayed as follows In order to access the...

Страница 32: ...gen com http www nitgen com 3 4 5 Register the terminal in ACM Pro Select the unregistered terminal and press Registration button to activate the screen below Enter device name and explanation to pres...

Страница 33: ...ADD USER USER ADMIN INPUT ID Authentication Type Card FP MCARD Authentication Condition OR AND MCARD is OR condition only MCARD is not admitted to set up state check only Password AUTO ADD FP UID FP1...

Страница 34: ...Terminal TERMINAL ID TERMINAL ID STATIC DHCP STATIC IP Subnet mask Gateway DHCP SERVER SERVER Port No OPTION ATTEND TYPE NONE M1 F1 F2 M2 F1 F4 M3 F1 F49 AUTO TNA NO YES SCREEN LANGUAGE ENGLISH 0 KOR...

Страница 35: ...ICE 0 5 BLE BLE READY TAMPER NO ALARM ALARM EXT DEVICE DOOR LOCK LOCK1 TYPE Not Use Strike OK Indication Motor1 Schedule alarm OPEN TIME 3 1 20sec LOCK2 TYPE NONE Fail Indication Motor2 Schedule alarm...

Страница 36: ...WIE26BIT WIE34BIT CUSTOM WIE OUTPUT TYPE NONE WIE26BIT WIE34BIT CUSTOM SiteCode More Information UID CARD STATE DB INFO USER CNT USER MAX ADMIN FP CNT FP MAX CARD CNT CARD MAX M CD CNT LOG CNT LOG MA...

Страница 37: ...RD TYPE RF SC CARD FMT STD FP1 1 x FP1 N x LFD xx AUTH TIME BEEP VOL VOICE VOL BLE Name MAC XXXXXXX BLE Name XXXXXXXXXXXXXXXXX TAMPER ALARM EXT DEVICE LOCK1 TYPE STRIKE OK OUT N O OPEN 3000ms LOCK2 TY...

Страница 38: ...a 05836 Tel 02 6488 3232 Fax 02 6488 3099 E Mail customer nitgen com http www nitgen com SN Serial Number RECOVERY INITIALIZE CONFIG LOG DB FACTORY SELF TEST INT DEVICE VOICE CARD FP SENSOR CAMERA LED...

Страница 39: ...ification conditions AUTO ADD Use to add Card or Fingerprint user automatically MODIFY Use to add certification conditions card or fingerprint of registered user DELETE Use to delete a registered part...

Страница 40: ...g or unchecking with MCARD it is only available via Server and Admin App There are AND and OR in authentication conditions In AND all authentication conditions should be satisfactory and then authenti...

Страница 41: ...6 2 4 INPUT CARD When you check Card as AUTH TYPE you will follow steps as below If you input CARD on Waiting state registration completes and INPUT OK screen is displayed EM CARD ex Card No 5byte 08...

Страница 42: ...registration User ID increases automatically 3 6 3 2 AUTO ADD This is the menu when registering the users continuously only by card After inputting the card INPUT OK is displayed on the screen If you...

Страница 43: ...6488 3232 Fax 02 6488 3099 E Mail customer nitgen com http www nitgen com 3 6 5 DELETE It is used when deleting the registered users 3 6 6 DELETE ALL It is used when deleting all the registered users...

Страница 44: ...d in the terminal but is not sent to server After converting Standalone mode into Network mode and accessing in server the authentication log saved internally is sent to sever If you want to see the a...

Страница 45: ...ation is processed Terminal Server Terminal Server After trying to do terminal authentication at first server authentication is processed Server Server only Authentication is processed only in server...

Страница 46: ...as a user wants DHCP Allocated flexibly It can be operated normally when using the router supporting DHCP If STATIC is used it is used when setting IP Subnet mark and Gateway address of the terminal...

Страница 47: ...rea 05836 Tel 02 6488 3232 Fax 02 6488 3099 E Mail customer nitgen com http www nitgen com 3 7 5 Server When the terminal accesses in server through the network set the information Default setting val...

Страница 48: ...as the same function as follows Category Explanation ATTEND TYPE AUTO TNA SCREEN LANGUAGE SHOW ID USER LOGO USER ID LEN DATE SAVE LOGO SAVE IMAGE SAVE TIMEOUT RESULT NET ERROR PING LOCKING NO USE USE...

Страница 49: ...2 are displayed in default screen F1 F4 F1 F4 Function Key is recognized and F01 F02 F03 F04 are displayed in default screen F1 F49 F1 F4 Function Key is recognized and F01 F02 F03 F04 F11 F49 are dis...

Страница 50: ...is used when modifying Year Month Day and time displayed in the default screen 3 8 3 1 Language It is used to change the voice language and menu text displayed on the screen Voice guidance is availab...

Страница 51: ...age shows the customer s logo or not in the default screen Category Explanation NO USE Use basically the provided default image USE Use the customer s logo image To use the customer s logo image you s...

Страница 52: ...it should change in the absence of a DB because it affects user s DB that is internally registered The setting range can be set from 4 to 16 If a user registered in the terminal exist you can t change...

Страница 53: ...set whether to save the authentication log in memory or not The default setting is YES 3 8 4 2 IMAGE SAVE It is used to set whether to save the captured photo from camera when authentication successe...

Страница 54: ...r over a period of time it is used to set whether there is a network communication error If PING doesn t come for a setting time in the server it retries to connect the terminal The setting range is a...

Страница 55: ...5 12F Daemyung Valeon bldg 127 Beobwon ro Songpa gu Seoul Korea 05836 Tel 02 6488 3232 Fax 02 6488 3099 E Mail customer nitgen com http www nitgen com The default screen is displayed as follows when s...

Страница 56: ...features as follows Category Explanation FP SENSOR 1 1 LEVEL 1 N LEVEL LFD LEVEL AUTH TIME BEEP Set Beep Sound VOICE Set Voice Sound BLE BLE registration mode TAMPER Set the alarm when opening termin...

Страница 57: ...t sets LFD LEVEL to prevent the duress fingerprint If setting LFD LEVEL higher and higher the ability to prevent the input of duress fingerprint produced by rubber paper film and silicon etc reinforce...

Страница 58: ...n retrial It sets the authentication level The voice level is available from 0 to 5 3 9 5 BLE When registering the terminal in Administrator s App this menu is required By using this menu it can make...

Страница 59: ...3099 E Mail customer nitgen com http www nitgen com 3 9 6 TAMPER When disassembling the terminal randomly it sets whether to sound the alarm If selecting 1 NO ALARM even if disassembling the terminal...

Страница 60: ...s Category Explanation DOORLOCK It sets the control device to lock through the internal relay RS485 It sets the devices using RS485 WIEGAND It sets the device using WIEGAND 3 10 2 DOORLOCK It is the m...

Страница 61: ...nds 3 10 2 3 LOCK2 type NONE When not using FAIL IND When connecting the light to mark authentication failure in Lock 2 MOTOR2 When connecting motor lock 3 10 2 4 LOCK2 OPEN TIME If Lock 2 sets FAIL I...

Страница 62: ...sed to detect the signal state of door open 3 10 2 7 DM1 DM1 Door Monitor 1 is the input port and it is used to detect the signal state of lock 3 10 2 8 DM2 DM2 Door Monitor 2 is the input port and it...

Страница 63: ...0 Lock Controller It controls LOCK through the other external module LC015 Lock Controller It controls LOCK through the other external module SR100 FP Dummy Reader When it installs the other FP dummy...

Страница 64: ...ishes devices and it can be set up 0 7 during RS484 communication 3 10 4 WIEGAND WIEGAND supports each one of Input port and Output port 3 10 4 1 WIE INPUT It is used to set the input type when workin...

Страница 65: ...ory Explanation NONE WIEGAND output port is not used WIE26BIT EM HID26 Card Module WIE34BIT Mifare Card Modules CUSTOM Use Access Manager program and set Wiegand format 3 10 4 3 CUSTOM BIT LENGTH It c...

Страница 66: ...itgen com SEND INFO Type None USER ID 26 Bit E Parity 1 Site Code 8bit ID 16bit O Parity 1 34 Bit E Parity 1 Site Code 8bit ID 24bit O Parity 1 If the length of the User ID greater than 8 and sent in...

Страница 67: ...ORK The setting information related to network OPTION TNA Screen setting Saving Time out Lock mode INT DEVICE Display the setting state related to the internal device EXT DEVICE Display the setting st...

Страница 68: ...ption setting value 3 11 5 INT DEVICE It displays the setting value related to the internal device 3 11 6 EXT DEVICE It displays the setting information related to the external device 3 11 7 I O PORT...

Страница 69: ...emyung Valeon bldg 127 Beobwon ro Songpa gu Seoul Korea 05836 Tel 02 6488 3232 Fax 02 6488 3099 E Mail customer nitgen com http www nitgen com 3 11 8 VERSION It displays the equipped module in the ter...

Страница 70: ...tegory Explanation INITIALIZE CONFIG LOG DB FACTORY SELF TEST INT DEVICE EXT DEVICE BACKUP LOG EXPORT USER EXPORT USER IMPORT FW UPDATE REBOOT REBOOT 3 12 2 INITIALIZE It is used to initialize CONFIG...

Страница 71: ...the user authentication log saved in the terminal 3 12 2 3 FACTORY INIT If trying FACTORY INIT setting data authentication log data and user registration information are initialized as setting state w...

Страница 72: ...R Fingerprint recognition test CAMERA Camera equipment test LED LED output test Voice Test When authentication successes it repeats and play voice guidance Card Test As you see below the screen displa...

Страница 73: ...e camera state is normal in the terminal to capture photos LED Test It is used to check whether the state is normal about RED GREEN and BLUE LED used to inform the operation state At intervals of 2 se...

Страница 74: ...32 Fax 02 6488 3099 E Mail customer nitgen com http www nitgen com DOORLOCK Test It is used to check the state of LOCK1 LOCK2 OPEN CLOSE from the terminal The procedure is as follows SENSOR IN It is u...

Страница 75: ...stomer service USB memory recommends using Sandisk NOTICE UDL Device is not supported for all USB memory UDL module may not work depending on the USB memory size manufacturer and method If Terminal de...

Страница 76: ...B If inputting user DB in the terminal all existing user DB are deleted If you need the existing user DB saved in the terminal back up first and try to input the user It opens USER NDB file in USB mem...

Страница 77: ...User Guide 77 12F Daemyung Valeon bldg 127 Beobwon ro Songpa gu Seoul Korea 05836 Tel 02 6488 3232 Fax 02 6488 3099 E Mail customer nitgen com http www nitgen com 3 12 5 REBOOT It is used when rebooti...