2) The EtherStretch Lyte system is designed to be used with an external network switch. The network switch can be
POE or a standard non-POE switch. With a POE switch the transmitter and camera must be connected for the POE
voltage to operate and power the transmitter and camera. The EtherStretch Lyte receiver and transmitter are shipped
configured to be used with a POE switch. If a non-POE switch is used the camera must be powered directly and the
receiver and transmitter units must be configured properly. For non-POE applications, look at the rear panel of the
receiver unit and turn “ON” the matching Power Selection DIP switch for a port. On the transmitter the POE Out
jumper must be in the “OFF” position. When the DIP switch is turned “ON” power is sent to the transmitter and an
LED below the BNC port will light.
Head-end Installation
ER8200C, ER16200C and ER24200C
1)
The ER8200C / ER16200C / ER24200C can be rack mounted, wall mounted or used as desk top unit. Use the in-
cluded mounting ears in the front or back of the unit depending on your needs. The mounting ears can also be
turned to the bottom of the unit for wall mounting if needed. When mounting the unit, be sure to follow these guide
lines.
a. Operating Ambient - Do not install the unit in an assembly where the ambient temperature could exceed 52°C
(125°F). NOTE: the ambient temperature in a closed or multi-unit rack assembly could greatly exceed the ambi-
ent temperature outside that assembly.
b. Air-Flow – Leave space on the sides of the unit for airflow into the cooling fans and some space on top of the
unit for air to exit the unit. Adequate air flow is required for safe operation.
c. Mechanical Loading – The mounting ears were designed for two ears to support one unit. Other configurations,
such as mounting other equipment directly on top of the unit or using only one mounting ear, could cause a haz-
ardous condition due to uneven or excessive mechanical loading.
d. Circuit Loading - Do not connect the unit to an electrical supply if the wiring or over current protection of the sup-
ply could be overloaded when the ratings listed on the unit are considered.
e.
Grounding (Earthing) - Reliable earth grounding of rack-mounted equipment should be maintained, use only 3
conductor equipment power cords. If the unit is plugged into a power strip or extension cord, that strip or cord
should have a ground (third) pin on its plug.
Network Ports
NITEK
®
Model ER24200C RECEIVER
ETHERSTRETCH LYTE
5
6
7
8
17
18
19
20
1
2
3
4
13
14
15
16
PORTS 1-24
Coax Activity:
Power Out:
Green (right)
Orange (left)
POWER
9
10
11
12
21
22
23
24
FRONT VIEW
Activity LED
Power LED
Coaxial Ports
Power Jack
23
19
20
Power
Selection
17
DOWN/OFF
UP/ON
PoE Out
Normal
12
11
10
9
24
22
21
8
7
6
5
18
4
3
2
1
16
15
14
13
Transmitter
Power Only
BNC LED On
Power
Selection
Power
Selection
Power Selection
MADE IN U.S.A.
RoHS
C O M P L I A N T
115 / 230 VAC
3/1.5 A
50/60 Hz
5A 250V
RISK OF FIRE -
REPLACE FUSE
AS MARKED
CAUTION
BACK VIEW
Power
Selection
Wall Mounting
Options
Rack Mounting
Options