2)  The  EtherStretch  Lyte  system  is  designed  to  be  used  with  an  external  network  switch.  The  network  switch  can  be 

POE or a standard non-POE switch. With a POE switch the transmitter and camera must be connected for the POE 
voltage to operate and power the transmitter and camera. The EtherStretch Lyte receiver and transmitter are shipped 
configured to be used with a POE switch. If a non-POE switch is used the camera must be powered directly and the 
receiver  and  transmitter  units  must  be configured  properly.  For  non-POE  applications,  look at  the  rear  panel  of  the 
receiver  unit  and  turn  “ON”  the  matching  Power  Selection  DIP  switch  for  a  port.  On  the  transmitter  the  POE  Out 
jumper  must be  in  the  “OFF”  position. When  the DIP  switch  is  turned  “ON”  power  is sent  to  the  transmitter  and an 
LED below the BNC port will light.  

Head-end Installation
ER8200C, ER16200C and ER24200C 

1)

The ER8200C / ER16200C / ER24200C can be rack mounted, wall mounted or used as desk top unit. Use the in-
cluded  mounting  ears  in  the  front  or  back  of  the  unit  depending  on  your  needs.  The  mounting  ears  can  also  be 
turned to the bottom of the unit for wall mounting if needed. When mounting the unit, be sure to follow these guide 
lines.
a.  Operating Ambient - Do not install the unit in an assembly where the ambient temperature could exceed 52°C 

(125°F).  NOTE: the ambient temperature in a closed or multi-unit rack assembly could greatly exceed the ambi-
ent temperature outside that assembly. 

b.  Air-Flow – Leave space on the sides of the unit for airflow into the cooling fans and some space on top of the 

unit for air to exit the unit.  Adequate air flow is required for safe operation. 

c.  Mechanical Loading – The mounting ears were designed for two ears to support one unit.  Other configurations, 

such as mounting other equipment directly on top of the unit or using only one mounting ear, could cause a haz-
ardous condition due to uneven or excessive mechanical loading. 

d.  Circuit Loading - Do not connect the unit to an electrical supply if the wiring or over current protection of the sup-

ply could be overloaded when the ratings listed on the unit are considered. 

e.

Grounding (Earthing) - Reliable earth grounding of rack-mounted equipment should be maintained, use only 3 
conductor equipment power cords.  If the unit is plugged into a power strip or extension cord, that strip or cord 
should have a ground (third) pin on its plug.

Network Ports 

NITEK

®

 Model ER24200C RECEIVER 

ETHERSTRETCH LYTE

5

6

7

8

17

18

19

20

1

2

3

4

13

14

15

16

PORTS 1-24

Coax Activity:
Power Out:

Green (right)
Orange (left)

POWER

9

10

11

12

21

22

23

24

FRONT VIEW

 

Activity LED

 

Power LED

 

Coaxial Ports 

Power Jack 

23

19

20

Power

Selection

17

DOWN/OFF

UP/ON

PoE Out
Normal

12

11

10

9

24

22

21

8

7

6

5

18

4

3

2

1

16

15

14

13

Transmitter 
Power Only
BNC LED On

Power

Selection

Power

Selection

Power Selection

MADE IN U.S.A.

RoHS

C O M P L I A N T

115 / 230 VAC

3/1.5 A

50/60 Hz

5A 250V

RISK OF FIRE -

REPLACE FUSE

AS MARKED

CAUTION

BACK VIEW

 

Power 

Selection

 

Wall Mounting 

Options 

Rack Mounting 

Options 