●●●●SSSSafety Equipment

afety Equipment

afety Equipment

afety Equipment    

・Be sure to equip motor with an “Earth-Leakage Circuit Breaker (ELCB)” or 

overload protection equipment.   

 

・Use this equipment only after confirming that the ratings are within the prescribe 

ratings stated on the motor’s name plate. 

・Be sure to comply with local electrical codes and regulations. 

 

  Caution:   

Caution:   

Caution:   

Caution:   

Be  sure  to  use  “Earth-Leakage  Circuit  Breaker  (ELCB)”  and 

overload protection device to avoid a damage to the equipment or 

motor burnout.

 

・Install a galvanometer, pressure sensor, or such other devices in the pump’s 

outlet line to avoid dry running. 

・The oil seals and packings cannot be used perpetually. 

・To prevent motor damage from coolant leak, it is recommended to insert a drain 

hose into seal drain hole. 

・To avoid motor damage, drain hose should be inserted in a way that the coolant 

can naturally flow down with its own weight through the hose.   

・Install the pump in a safe location, or provide a protective cover or device to avoid   

accidental coolant leakage.

 

 

●●●●Safety Measures

Safety Measures

Safety Measures

Safety Measures    

・Keep children or other people incapable of judging risks away from the pumps. 

・Install protective device to prevent fingers, hands or other objects from getting 

caught in the rotating or moving parts. 

 

  Warning

 

Getting  your  fingers,  hands  or  articles  caught  in  rotating  or 

moving parts may cause an unexpected injury

 

・Do not touch a pump or motor during or immediately after the operations.

 

  Warning

 

The motor and pump surface may heat up while in an operation. 

Be  careful  not  to  touch  the  pump  and  motor  while/or 

immediately after an operation.

 

 

  Danger

 

Do not operate the pump in a place having a risk of explosion or 

extremely dusty place. Do not place any flammable liquids or 

materials in the area surrounding the motor. Such items could 

cause explosion or fire.

 

Содержание NOP E Series ES

Страница 1: ...r the correct and optimum use of NOP coolant unit Improper use of the pump can cause personal injury and damage to property and may void the warranty Save this manual for future reference and keep Sav...

Страница 2: ...for the Pump 12 12 12 12 Torque Applied on Pipe Connection 12 Connecting the Pipes 12 Pipes and Pipe Joints 12 Electric Wiring Electric Wiring Electric Wiring Electric Wiring 13 13 13 13 For Operation...

Страница 3: ...r Such items could cause explosion or fire Make sure that the power is disconnected before installation maintenance or inspections to avoid the risk of electric shock Transporting installation plumbin...

Страница 4: ...ed filters affect the pump performance and abnormal noise vibration or flow deficiency may occur Tramp oil or foam may affect Turbulence filter performance Installation of partition plate as illustrat...

Страница 5: ...n HV600 Extremely hard materials such as Inconel Titanium Tungsten can drastically shorten the pump service life Do not use hardened steel carbon fiber glass fiber containing materials carbon material...

Страница 6: ...To avoid motor damage drain hose should be inserted in a way that the coolant can naturally flow down with its own weight through the hose Install the pump in a safe location or provide a protective c...

Страница 7: ...ution Assembling the pump in a wrong orientation will damage the motor Install the pump unit in an up right position Caution If the installation site is not level or if there is forcible installation...

Страница 8: ...igure 2 Dimensional drawing Typical Motor type A3 Dimensional drawing Typical Motor type A3 Dimensional drawing Typical Motor type A3 Dimensional drawing Typical Motor type A3 D D D Drain rain rain ra...

Страница 9: ...t the pump in the tank at least 1 mm above the tank floor This is to ensure enough clearance to prevent the pump from sucking the sediments of sludge or metal chips on the tank floor To prevent the pu...

Страница 10: ...1 able 1 F F F Filtration iltration iltration iltration P P P Performance erformance erformance erformance Straight oil is only applicable to 50 m filter Caution Suction of excessive amount of needle...

Страница 11: ...Contaminant Contaminant Contaminant D D D Drain rain rain rain P P P Port ort ort ort P P P Performance for reference only erformance for reference only erformance for reference only erformance for re...

Страница 12: ...Air ir ir ir Entering Entering Entering Entering into into into into the the the the System System System System Caution The pumps can make louder noise at the first run but will stop once the trapped...

Страница 13: ...es ipes To prevent leaks and air entry make sure all pipe connections are securely tightened and completely sealed Be sure to use pipe supports so that the pipes are self supported and no weight will...

Страница 14: ...Our NOP s pre installed motor a 3 phase type is when viewed from the suction side designed to rotate in counter clockwise if wired as illustrated in figure 8 below Figure 8 Figure 8 Figure 8 Figure 8...

Страница 15: ...a half year Concentration level of the coolant Keep the level within the range specified by the coolant manufacturer The viscosity of straight oil Oil viscosity must be below 32 mm2 s Fluid temperatur...

Страница 16: ...Required Required F F F Flow low low low R R R Rate ate ate ate Select a pump by referring to the catalog drawings or other materials Note that discharge rate is subject to the pump type temperature...

Страница 17: ...explode or cause fire Operating Operating Operating Operating A A A Ambient mbient mbient mbient T T T Temperatures emperatures emperatures emperatures The permissible ambient temperature range is fr...

Страница 18: ...uired Required Required Required P P P Power for the ower for the ower for the ower for the P P P Pump ump ump ump Select a pump with an adequate margin with reference to the performance carve in the...

Страница 19: ...pump suction performance Caution Make sure there is no trapped air in inlet line It may decrease the performance of Turbulence filter cause filter clogging and damage the pump Caution Clean the perfo...

Страница 20: ...pump or pipes On the first run after long term storage or immediately after replacing coolant pump often doesn t discharge due to air inside the pump Perform air bleeding on pump or piping If check va...

Страница 21: ...shing and filter performance will be restored Follow the steps shown below to perform backwashing T T T Table able able able 10 10 10 10 Backwashing Circuit Backwashing Circuit Backwashing Circuit Bac...

Страница 22: ...81 3 3 3 3 3436 3436 3436 3436 1777 1777 1777 1777 Sumitomo Real Estate Higashi Shimbashi Sumitomo Real Estate Higashi Shimbashi Sumitomo Real Estate Higashi Shimbashi Sumitomo Real Estate Higashi Sh...

Отзывы: