3
Pump Installation
●
Installation
・
The pump should be installed at a position that is within 1m above or below the
oil surface level.
・
It is advisable to mount the pump at a position where the suction port is above
the height of the oil surface level.
・
Please consult us if the pump should be used outside the specification range as
stated above.
Caution:
Installing the pump at a height of more than 1m above the oil
surface could result in poor suction, depending on the operating
conditions.
●
Installation Positions for the Trochoid Pump, Trochoid Pump with Motor,
Trochoid Pump with Motor and Base Coupling, and Lunary Pump with
Motor and Base Coupling
・
There are no particular restrictions on the mounting directions when installing
only the pump itself.
・
When installing a Trochoid pump with a motor, the pump cannot be installed in a
position higher than the motor (as seen from the horizontal position).
・
When installing a Trochoid pump with a motor and a base coupling, the
foundation where the base plate will be attached must be level.
・
Align the attachment anchor so that it can be smoothly fitted to the base plate
and the motor attachment holes.
Caution:
The motor may get damaged if the motor and Trochoid pump are
installed incorrectly.
Caution:
If the installation site is not level, or if there is forcible installation in
which the installation holes are not in exact alignment, the angle
plate or base may get damaged or the axis may be deviated, which
result in pump galling and ruining the pump.
Installation Site
The equipment should not be installed in locations with lots of dust, high or low
temperatures (refer to P.10 "Ambient Temperature"). Please consult us onwhat
measures can be taken when the equipment must be used in special
environments (e.g. a place in which the pump will be exposed to water, place
with high vibration or high humidity) other than the typical indoor installation
sites.