background image

 

15 

Transducer wiring 

When using double channel, Channel 1 is connected with 50kHz and Channel 2 is 

connected with 200kHz. When using single channel, connect with Channel 1. 

 

DF612 -- BP60-200-15L 

DF1011 -- TGM60-50B-15L, 

wiring method: 

Shielded wire 

  Pin 1 of 5-pin plug 

Other signal wires 

  Pin 3/ Pin 4 of 5-pin plug 

DF2022 -- TGM50/200B-15L wiring method: 

Shielded wire 

  Pin 1 of 5-pin plug 

White/ Black wire (50kHz) 

  Pin 3/ Pin 4 of 5-pin plug 

Red/ Green wire (200kHz) 

  Pin 2/ Pin 5 of 5-pin plug 

DF5088 

– CM488 wiring method: 

Shielded wire 

  Pin 7 of 7-pin plug 

Cut off violet and orange wire from the root. 

Yellow/ Black wire (50kHz) 

  Pin 3/ Pin 4 of 7-pin plug 

Blue/ Black wire (200kHz) 

  Pin 2/ Pin 5 of 7-pin plug 

White/ Brown wire (Temperature) 

  Pin 1/ Pin 6 of 7-pin plug 

DF5099 

– CM158 wiring method:   

Shielded wire 

  Pin 1 of 5-pin plug   

Cut off orange and brown wires from the root. 

Blue-white/ Black-white wire (50kHz) 

  Pin 3/ Pin 4 of 7-pin plug 

Содержание DF Series

Страница 1: ...Doc No NLT DFXXXX SSEN Version V160106 10 INCH LCD DIGITAL FISH FINDER OPERATION MANUAL Model DF SERIES ...

Страница 2: ...Operation 3 Keyboard 3 Operation 4 Fixed key functions 4 POWER 4 RANGE 4 SHIFT 4 GAIN GAIN 1 GAIN 2 4 Color single freq fish finder 4 ZOOM 4 Operation 5 BRILL 5 MENU 5 AUTO 5 FREQ 5 MODE 5 Arrows UP DOWN LEFT RIGHT 6 MENU contents and factory setting 6 MENU 1 6 MENU 2 7 Setting on MENU 8 ...

Страница 3: ... 9 Pulse Width 9 TVG 10 Noise Rej 10 Echo Color 10 Palette 10 Depth Alarm 11 Upper Limit 11 Lower Limit 11 Zone Limit 11 How to get the steady data 12 Installation 13 Operating unit installation 13 Installation 14 Connection 14 Power Supply 14 VGA 14 Transducer wiring 15 ...

Страница 4: ...22 single 50 200 kHz 1500 1500W CM422 AIRMAR DF5066 double 50 200 kHz 1800 600W TD67 HONDEX DF5088 double 50 200 kHz 2000 1000W CM488 AIRMAR DF5099 single 50 kHz 2500W CM158 AIRMAR Features Digital signal processing without IF transformer and advanced technology Digital signal reception with low background noise and high sensitivity Digital signal conditioning no change with temperature and high s...

Страница 5: ... color LCD 640X480 pixels Background Grey Blue D Blue Black Echo colors 16 echo levels and 6 kinds of color configuration Time scale 30s continuously move left Range scope 5 10 20 30 40 50 60 80 100 120 150 180 200 250 300 400 500 600 800 1000 1500 2000m Shift range 5 500 m Alarm shallow alarm prior fish alarm Alarm mode buzzing letters glittering on screen Environment Working temperature 10 40 co...

Страница 6: ... area toward sea surface or sea bottom BRILL Adjust the brightness of display MENU Open MENU 1 MENU 2 and EXIT AUTO Turn on off Auto range Arrows Right Left Adjust Pic speed Up Down adjust the echo color Select items or change the settings in MENU FREQ Select display mode Low freq High freq Low freq High freq High freq Low freq MODE Switch Normal mode Bottom Z Fixed Z Dual freq Fish finder Single ...

Страница 7: ...splay depth becomes to 5m and display range becomes to 5 10m Shift range 5 500m GAIN GAIN 1 GAIN 2 This adjusts the sensitivity to distinguish the bottom or fish school easily Dual freq fish finder GAIN 1 adjust the sensitivity of 50 kHz signal received GAIN 2 adjust the sensitivity of 200 kHz signal received Color single freq fish finder This facilitates clear observation by eliminate weak echo Z...

Страница 8: ...ENU MENU button facilitates selection of MENU 1 MENU 2 and EXIT AUTO AUTO button is used to turn on or off Auto Range FREQ Frequency displayed toggles among 50 kHz L 200 kHz H 50 200 kHz L H and 200 50kHz H L MODE Three modes a re optional toggled by pressing MODE key Normal mode Display normal echo graphic Bottom Z Bottom contour is indicated as a straight line and expansion view of certain area ...

Страница 9: ...olor MENU contents and factory setting Note In the following MENU list the factory setting is marked with grey back color such as 100m MENU 1 Pic Speed 0 1 2 3 4 2 4 Auto Range Off On Max A Range 30m 100m 200m 300m 500m 800m Max Zoom 2 5 5 10 Noise Rej Off Low High Output Power 0 10 20 30 40 50 60 70 80 90 100 TVG Off Low Standard High White Line off On Press MENU key to MENU 2 ...

Страница 10: ...or such as 100m Back Ground Grey Blue D Blue Black Palette 0 1 2 3 4 5 Fish Alarm Off Small Big Depth Alarm Off Upper Zone Lower Upper Limit 1m Lower Limit 10 m Lower Limit Upper Limit 10 m 501m Pulse Width Short Standard Long Unit m fm Press MENU or OK key to EXIT Press MENU key to MENU 2 ...

Страница 11: ...ays shown on the optimum position of the screen lower half area When auto range function is operating DEPTH key is non functional Set Auto range on MENU 1 Off On Max A Range It sets maximum depth when auto range is operating Set Max A Range on MENU 1 30 100 200 300m 500m 800m Max Zoom Set zoom rate in MENU 1 2 5 5 10 Fish Alarm When the response to be supposed fish school is displayed and the fish...

Страница 12: ...fers from surrounding brightness It becomes easy to see the display by selecting different the background color Select Back Ground color in MENU 1 Grey Blue D Blue Black Pulse Width Normally pulse width is set to short automatically according to set displayed depth range Set Pulse Width on MENU 1 Short Standard Long ...

Страница 13: ...o interferences of the same frequency transducers nearby are eliminated Set Noise Rej on MENU 1 Off Low High Echo Color This function facilitates clear observation by eliminate weak echo Set Echo Color by up down arrows 04 16 Palette Reflected signals of sound wave are converted into 16 ranks of digital signals according to the strength of response 16 ranks of color are arranged and it is called c...

Страница 14: ...r depth are set in MENU 2 Upper limit and Lower limit Upper Limit Set Upper depth alarm value Set Upper Limit in MENU 2 1m Lower Limit 10 m Lower Limit Set Lower depth alarm value Set Lower Limit in MENU 2 Upper Limit 10 m 501m Zone Limit Set Zone depth alarm value Set Zone Limit in MENU 2 Upper Limit Lower Limit Upper Lower Zone ...

Страница 15: ... signal received GAIN may be adjusted from the min value to max value and you can get the appropriate sensitivity at one time point which comes before the time point of showing littery wave on screen Color Del suppress unwanted echoes and noise to be adapted with different waters environment Too low Appropriate Appropriate but littery Too high Del Color is too much ...

Страница 16: ...13 Installation Operating unit installation Installation mode Table Unit mm ...

Страница 17: ...14 Installation Connection Power Supply VGA VGA interface realizes external 15 32 inch LCD to display the echo graphics Wiring method Positive Pin 1 of 2 pin plug Negative Pin 2 of 2 pin plug 1 DC 2 DC ...

Страница 18: ... wire Pin 1 of 5 pin plug White Black wire 50kHz Pin 3 Pin 4 of 5 pin plug Red Green wire 200kHz Pin 2 Pin 5 of 5 pin plug DF5088 CM488 wiring method Shielded wire Pin 7 of 7 pin plug Cut off violet and orange wire from the root Yellow Black wire 50kHz Pin 3 Pin 4 of 7 pin plug Blue Black wire 200kHz Pin 2 Pin 5 of 7 pin plug White Brown wire Temperature Pin 1 Pin 6 of 7 pin plug DF5099 CM158 wiri...

Отзывы: