Wind speed alarm level
There are two levels alarm. If the wind speed achieves or exceeds the first
level setting, the first level alarm is triggered with 1
st
form of sound/light.
If the wind speed achieves or exceeds the second level setting, the second
level alarm is triggered with 2
nd
form of sound/light.
Set the wind alarm “dividing value”
Press
[F]
once on the main unit to enter the “wind alarm dividing value
setting”. “
dId
” is flashing. The first line LEDs show “
dId
”, then press
[
▲
]
or
[
▼
]
to set the dividing value. The second line LEDs show the setting value.
The dividing value here after will be referred to as
“X”.
Set the first level alarm value
Press
[F]
twice on the main unit to enter the “1
st
level alarm setting”. “
AL1
”
is flashing. The first line LEDs show “
AL1
”, then press
[
▲
]
or
[
▼
]
to set the
value of the 1
st
level alarm. The second line LEDs show the setting value.