background image

                                                                  

10 

Function and Operation 

Speedlog Data Input--VHW 

$--VHW, x.x,T , x.x,M , x.x,N , x.x,K*hh<CR><LF> 

1            2 

   

     

4

 

(1)    Heading, degrees True 
(2)    Heading, degrees Magnetic 
(3)    Speed, knots 
(4)    Speed, km/hr 

Gyro Data Input--HDT 

$--HDT, x.x , T * hh<CR><LF> 

     

         

1

     

2

     

(1) Heading, degree true 
(2) T = true 
(3) Checksum value 

 

 

 

 

 

 

 

 

 

 

 

Содержание AM706-H

Страница 1: ...Website www ninglutech com Document NLT AM706 SSEN Edition V190314 Anemometer AM706 H Operation Installation Manual...

Страница 2: ...ed direction Max speed Average speed mode MENU Set Wind Alarm Speed Unit Avg Time Input Show Language Back Color and Dig Color Calibration After finishing the main unit AM706E installation and power o...

Страница 3: ...4 Day Night Mode 4 MODE 4 Arrow Keys 5 MENU 5 Wind Alarm 5 Speed Unit 6 Avg Time 6 Input Show 6 Language 7 Back Color 7 Dig Color 7 Default 7 Send Ture 7 Data transmission for NMEA0183 8 Main Unit Out...

Страница 4: ...art 13 Calibration 14 Installation 15 Installation of Main Unit AM706E 15 Power Adapter Installation 16 Installation of Wind sensor AM706H 17 Wiring Explanation 18 System View 18 Wiring Diagram of AM7...

Страница 5: ...s Sensor AM706H should be installed in the place with free wind in the ship System Composition Main Unit AM706E Direction Display Analog and digital display of relative to the bow and true wind direct...

Страница 6: ...t the rotor is spinning to calculate the wind speed The wind direction sensor has a wind vane which points in the direction that the wind is coming from The wind direction sensor electronically senses...

Страница 7: ...he system Brightness In Day Night mode press the brightness key to adjust the screen brightness There are 9 levels for selection Power on off Menu OK Mode Brightness Arrow keys Day Night Mode Wind Dir...

Страница 8: ...switch the day mode and night mode MODE Press MODE key to select Relative Mode relative speed relative angle max speed average speed and True Mode relative speed relative angle true speed true Angle...

Страница 9: ...ish Back Color Light Blue Blue Black Light Blue Dig Color Yellow in Blue Green in Black White in Black Yellow in Blue Default Off Reset Off Send Ture Yes No No Wind Alarm Set the relative wind speed a...

Страница 10: ...nd press left right arrow keys to select speed unit 1 60m s and default is Off Setting Range is m s km h and knots and default is m s Avg Time Set the computing period of the max speed and average spe...

Страница 11: ...select the colors Setting Range is Light Blue Blue and Black and default is Light Blue Dig Color Set the window and number colors Press up down arrow keys to select the item Dig Color and press left...

Страница 12: ...h M m s N knots 5 Status A Data Valid V Data invalid 6 Checksum GPS Data Input RMC RMC hhmmss ss A llll ll a yyyyy yy a x x x x xxxxxx x x a a hh CR LF 1 2 3 4 5 6 7 8 9 10 1 UTC Time 2 Status A Data...

Страница 13: ...valid 6 Checksum value Speedlog Data Input VBW VBW x x x x A x x x x A x x A x x A hh CR LF 1 2 3 4 5 6 7 8 9 10 11 1 Longitudinal water speed Knots 2 Transverse water speed Knots 3 Status water spee...

Страница 14: ...g Data Input VHW VHW x x T x x M x x N x x K hh CR LF 1 2 3 4 1 Heading degrees True 2 Heading degrees Magnetic 3 Speed knots 4 Speed km hr Gyro Data Input HDT HDT x x T hh CR LF 1 2 3 1 Heading degre...

Страница 15: ...5W 24V DC NMEA Input Baud Rate 4800bps 9600 bps for GPS data input Wind Output Baud Rate 4800bps Data Input RS422 and NMEA0183 Standard Sensor Dimension AM706H H590mm Activity Radius 320 mm Environme...

Страница 16: ...12 Specification Technical Specification Wind Speed Range 0 60m s Wind Speed Accuracy 5 min0 1m s Wind Direction Range 0 359 Wind Direction Accuracy 1 Min Start Speed 0 5m s...

Страница 17: ...Sensor Part When there is ice or dirt on sensor to disturb the normal work please clear in time Regularly check external mounting bolts to avoid looseness and the abrasion and ageing of cables When t...

Страница 18: ...14 Calibration Calibration of AM706 wind vane after finishing the installation Press POWER key to turn power on...

Страница 19: ...ounting methods table hanging and flush mounting The holder supplied by original factory setting is used in table and hung mounting For flushing mounting embed the main unit into the bridge control pa...

Страница 20: ...16 Installation Power Adapter Installation Power adapter GA 240150 AC220 110V to DC24V adapter holder and screws Unit mm...

Страница 21: ...lace with free wind in the ship Mounting Holder is 40 and Activity Radius is 320 mm After finishing the installation of the main unit and sensor please make the calibration Note 1 The location of the...

Страница 22: ...18 Wiring Explanation System View Wind Sensor AM706H...

Страница 23: ...19 Wiring Explanation Wiring Diagram of AM706E Back Cover...

Страница 24: ...20 Wiring Explanation System External Wiring Diagram...

Страница 25: ...2 1 0 3 1 5 1 5 11 28 5 32 6 103 117 2 1 6 3 3 6 11 12 32 7 36 9 118 133 3 3 4 5 4 12 19 13 37 0 41 4 134 149 4 5 5 7 9 20 28 14 41 5 46 1 150 166 5 8 0 10 7 29 38 15 46 2 50 9 167 183 6 10 8 13 8 39...

Отзывы: