14
ENGLISH
5 Protection against overheating
The cabinet has double protection against overheating.
Overheating protection
- reset by the user.
Main regulation
- reset by the service personnel.
5.1 Overheating protection
If the cabinet overheats during operation, the electric elements turn off and the fan continues to run.
The display will flash with
‘ERR 05’.
When the temperature in the cabinet is down to an acceptable level (within approx. 4 min.), the display
will show
‘ERR 05
’ with a fixed display and the text
‘OH PROTECTION’
will be rolling on the lower line.
The overheating protection can then be reset by pressing and holding the
START/STOPP
button for
approx. 4 seconds.
5.2 Main regulation
If the drying cabinet should overheat for some reason during the drying process, the main regulation
will be triggered. The main regulation has to be reset manually.
5.2.1 Reset
A reset is performed with the button directly on the overheating protections. See figure and look for the
cause when performing the reset. Are both fans functional? Has the filter been cleaned?
1
Remove the front hatch by loosening the two screws on the lower edge.
See chapter 8.
2
Push in the button on the overheating protection that has been pushed out. Examine both
protections.
Overheating protection
Front hatch
Содержание PRO FT 120 FL
Страница 24: ...Gematech Innovation...