background image

7

42445 Avenida Alvarado, Temecula, CA  92590

 (800) 451-9343 · www.nimbuswater.com

State of California

Department of Public Health

Water Treatment Device

Certificate Number

Date Issued:  May 10, 2011

Trademark/Model Designation

Replacement Elements

2076

11-

Nimbus Water Maker Five  WM5-50

TF50 (4 stage cartridge)   104592

GAC postfilter

104803

Manufacturer:

Nimbus Water Systems

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section

116830 of the Health and Safety Code for the following health related contaminants:

Cysts (protozoan)

Arsenic V
Fluoride
Lead

Microbiological Contaminants and Turbidity

Inorganic/Radiological Contaminants

Organic Contaminants

Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified

for cyst reduction may be used on disinfected waters that may contain filterable cysts.

1

Claims for arsenic reduction shall only be made on water supplies maintaining detectable residual free chlorine at the

reverse osmosis (RO) system inlet.  Water systems using an in-line chlorinator should provide a minimum of 1 minute

chlorine contact time before the RO system.

Rated Service Capacity:

14.61 gal/day

Rated Service Flow:

Conditions of Certification:

Содержание Five Water Maker WM5-50

Страница 1: ...0 5 Stage Reverse Osmosis System Rev 10 14 42445 Avenida Alvarado Temecula CA 92590 800 451 9343 FAX 951 894 2801 www nimbuswater com System tested and certified by NSF International against NSF ANSI Standard 58 for the reduction of substances specified on the performance data sheet ...

Страница 2: ... Model Date Code Install Date Sold by Installed By Service Center Phone Number WaterMaker Five WM5 50 Please fill out the following information at the time of installation Save for future reference ...

Страница 3: ... is functioning properly a water sample must be sent in to Nimbus every 6 months for a free diagnosis of your membrane performance To send a water sample use two clean containers and fill one with 1 2 cup of tap water and the other with 1 2 cup of RO water Clearly label each sample Send the samples to the address listed on the cover of this manual attention Water Sample Testing Nimbus will test th...

Страница 4: ...umes no liability for the determination of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Warranty does not cover any Manufacturer supplied items that are defective as a result of the use of improper parts equip ment or materials This warranty does not cover alterations or modifications of the unit or fai...

Страница 5: ...performed under standard laboratory conditions actual performance may vary Incoming water must be free of potential membrane foulants such as Iron Hydrogen Sulfide and Manganese Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage Recovery rating mean...

Страница 6: ...s type of service Reverse osmosis RO water treatment systems are very effective at removing pentavalent arsenic RO systems do not remove trivalent arsenic from water very well A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A comb...

Страница 7: ... health related contaminants Cysts protozoan Arsenic V Fluoride Lead Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organic Contaminants Do not use where water is microbiologically unsafe or with water of unknown quality except that systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts 1 Claims for arsenic reduction...

Страница 8: ... H Drain tubing 1 4 black I Faucet tubing 3 8 blue J Four stage desalinator K Feed water tubing 1 4 green L Feed valve assembly with adapter and shut off valve M Carbon post filter A B J E F G D K L M I H C not shown behind cover Pressure 40 80 psi 275 kPa 552 kPa Temp 40 F 100 F 4 C 38 C TDS 2000 mg L Chlorine 1 0 mg L Turbidity 1 NTU SDI 5 pH 4 8 Performance Specifications Feed water must be pot...

Страница 9: ...ing located on the faucet base 7 Slide white plastic spacer open end up onto the threaded faucet stem 2 Note This spacer may be omitted if faucet is installed in a granite countertop or countertop with similar thickness 8 Loosely thread the 3 8 washer 3 the serrated washer 4 and mounting lock nut 5 onto the threaded stem Leave enough space for the slotted washer which will be used in step 11 9 Thr...

Страница 10: ...small adhesive foam pad from the small parts bag Fig 2 3 Place the adhesive foam pad on the inside of the the drain saddle front aligning the holes 4 Position the drain saddle on the drain pipe under the sink between the P trap and the sink connection Orient the drain saddle so that the opening is on the side of the drain pipe 5 Using the bolts and hex nuts hand tighten the saddle bracket evenly u...

Страница 11: ...e first tankful of flow This flushing procedure will allow any sanitizer or carbon fines to pass from the system 2 Initial tank filling will take approximately one hour based on average feed pressure When the tank is full the water pressure will have risen to the point where the automatic shut off valve inside the system will stop the feed flow through the system Actuation of the automatic shut of...

Страница 12: ...e connectors until it snaps into place properly 4 All tubing connections especially push in quick connections are fully inserted 5 Tubing connected between the faucet and the drain saddle fitting the fitting attached to the sink drain pipe runs down hill to the drain There should be no loops or places where water would not flow out to the drain 6 Angle stop valve is open The small shut off valve o...

Страница 13: ...p will result in accidental leaks and flooding 7 Open the small shut off valve on the feed valve assembly Open the dispensing faucet 8 Close dispensing faucet after water starts running 9 Observe system for any leaks especially at newly re placed cartridge 10 Open the tank shut off valve 11 The system should be flushed at least once as described above under Section 8 Post Filter Replacement 1 Clos...

Страница 14: ......

Отзывы: