4.2 

Switching on the 
vacuum cleaner

4.2.1 Switch position “I”

1. Turn the switch to position 

„I“.

The vacuum cleaner motor 
starts.

4.2.2  Switch position „auto“

Before switching the switch to position 
„auto“, ensure that the tool connected 
to the appliance socket is switched off.

1. Turn the switch to position 

„auto“. The vacuum cleaner mo-
tor starts when the connected 
appliance is switched on.

2.  When the power tool is switched 

off the vacuum cleaner contin-
ues to run for a short moment 
so that any dust in the suction 
hose is conveyed to the safety 
filter bag.

4.1.3 Connecting electrical 

appliances

1. 

Ensure that the electrical 
appliance is switched off.

2.  Connect the electrical appli-

ance to the appliance socket 
on the control panel.

To comply with regulations, only ap-
proved dust producing tools should 
be connected.
The maximum power consumption 
of the connected power tool is stat-
ed in section 9.4 “Technical data”.

The hose diameter and the setting 
for the suction hose diameter must 
be the same.

Hose

ø

Hose diameter 

setting

ø27

ø27

ø32

ø32

ø36

ø36

ø50

ø50

0

0

0

0

0

3

3

6

5

2

2

7

0

0

0

0

0

3

3

6

5

2

2

7

The hose diameter and the setting 
for the suction hose diameter must 
be the same.

Hose

ø

Hose diameter 

setting

ø27

ø27

ø32

ø32

ø36

ø36

ø50

ø50

4.2.3  Suction power control

The motor speed and the suc-
tion power can be varied with 
the suction power control. This 
allows precise adaptation of 
the suction power for different 
cleaning tasks.

0

0

0

0

0

3

3

6

5

2

2

7

4.3 

Check volume flow 
monitor

Before picking up dust with maxi-
mum room concentration values:

1.  Check that all the filters are 

present and properly fitted.

2.  When the motor is running, 

hold the suction hose shut. 
An acoustic warning sounds 
after approx. 1 second.

Содержание ATTIX 360-2M

Страница 1: ...sull uso 61 75 norsk Driftsinstruks 76 90 svensk Bruksanvisning 91 105 dansk Driftsvejledning 106 120 suomi K ytt ohje 121 135 slovens i Navodilo za uporabo 136 150 hrvatski Uputstvo za rad 151 165 sl...

Страница 2: ...TTIX 360 2M ATTIX 550 2M ATTIX 560 2MXC ATTIX 751 2M ATTIX 761 2MXC auto 1 4 3 5 6 7 3 11 9 8 10 ATTIX 3 14 auto 9 8 2 3 5 6 7 ATTIX 5 1 4 auto 14 ATTIX 7 2 3 4 1 5 5 6 8 10 12 12 13 10 9 14 auto auto...

Страница 3: ...2 3 Suction power control 6 4 3 Check volume flow monitor 6 4 4 Acoustic warning 7 4 5 Cleaning the filter element ATTIX 360 2M 7 4 6 Cleaning the filter element ATTIX 560 2MXC 761 2MXC 7 5 1 Techniqu...

Страница 4: ...e country of use ob serve recognized regulations for safety and proper use Do not use any unsafe work techniques Purpose and intended use The vacuum cleaners described in this operating manual are sui...

Страница 5: ...level indicator hose ATTIX 560 2MXC 761 2MXC to limit the water level and check that they are not damaged See section 5 for information on handling liquids and hazard ous dust Electrical components C...

Страница 6: ...there is no danger for maintenance staff or other persons In the maintenance area use filtered compulsory ven tilation wear protective clothing clean the maintenance are so that no harmful substanc e...

Страница 7: ...on of the vacuum cleaner The mains plug should not be in serted into a socket 3 To pick up dust with maxi mum room concentration values Insert the filter bag into the dirt tank according to the instru...

Страница 8: ...e socket on the control panel To comply with regulations only ap proved dust producing tools should be connected The maximum power consumption of the connected power tool is stat ed in section 9 4 Tec...

Страница 9: ...ng stream of air removes attached dust from the slats of the filter elements To ensure that suction perform ance is always at its best the filter element is automatically cleaned during operation We r...

Страница 10: ...hould be washed and dried or replaced by a dry element be fore dry substances are picked up Always use a filter bag waste bag that is suitable for the type of dust see table ATTIX 360 2M Type of dust...

Страница 11: ...ount of foam use foam killer Nilfisk Alto Foam Stop see section 9 5 Accesso ries for order number 6 After finishing work 6 1 Switching the vacuum cleaner off and storage 1 After picking up hazardous d...

Страница 12: ...aining clamps 1 and remove the intermediate ring 2 from the tank 3 Carefully remove the waste bag connection from the inlet fitting 4 Close the waste bag using the cable binder 3 5 Dispose of the dirt...

Страница 13: ...r Before reinserting the suction hose 5 Clean the inlet fitting and hose collar Only after picking up harmless dust without a filter bag 7 2 4 Emptying the dirt tank ATTIX 7 1 Remove the upper section...

Страница 14: ...e filter holder and turn it clockwise to secure it firmly 10 Dispose of the used filter ele ment in accordance with legal regulations Never use the vacuum cleaner without a filter During the following...

Страница 15: ...onnect mains fuse Overload protection switch has tripped Switch off the vacuum cleaner and allow it to cool for approx 5 minutes If the cleaner can not be started again contact the Nilfisk Alto servic...

Страница 16: ...sult of technical advances 9 3 Tests and approvals The vacuum cleaners have been tested as specified in IEC EN 60335 2 69 including appendix AA All the requirements were fulfilled for equipment in dus...

Страница 17: ...e bag 5 pcs 302000804 302000728 Filter element 302000461 302000726 Cloth insert filter 302000606 302000525 751 2M 761 2MXC Filter bag 5 pcs 302001484 Waste bag 5 pcs 302001480 Filter element 302000461...

Страница 18: ...OWERBANK 7AY ILWILLY NDUSTRIAL STATE 5 0ENRITH UMBRIA 1 4EL AX MAIL SALES NILFISK ALTO CO UK 7EB WWW NILFISK ALTO CO UK 93 4 3 ALAYSIA 3DN HD 3 ALAN 0 4AMAN 0ERINDUSTRIAN 0 32 AMANSARA UALA UMPUR ALA...

Отзывы: