SET-UP & OPERATION

1.

 

Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness.    

 

Make sure hoses are in good condition and the spray nozzle(s) is tight.

2.  If not using the auto-dump feature, just make sure the brass cap is on the drain hose connector on  

 

the front of the base of the machine.

 

If you choose to use the auto-dump feature, remove the brass cover on the hose connector on the  

 

front of base of the machine, attach a hose, and place the open end of the hose in a drain. Make sure  

 

the recovery tank drain gate is closed, and the lid is tight on the recovery tank.  

3.  If you choose not to use the auto-fi ll feature, just fi ll the tank with water and cleaning   

 

 

chemical.  Follow chemical directions regarding dilution and mixing.  Do not use harsh chemicals; they  

 

may damage seals in pumps and valves, and cause the pump to wear prematurely. . 

 

If you choose to use the auto-fi ll feature, connect the fi ll hose to the auto-fi ll connector (located over  

 

the solution tank fi ll hole). Turn on the water source -- HIGH PRESSURE IS NOT NECESSARY --  

 

and allow the tank to fi ll with water.  When using the auto-fi ll system, the auto-fi ll fl oat will  

 

 

automatically turn on and turn off as the tank empties and then fi lls.  

  NOTE: Never put water with a temperature exceeding 54 

°

C in the solution tank

4.  Pre-spray the area to be cleaned, with a pump-up sprayer, while the tank is fi lling.  Follow chemical  

 directions.
5.  Plug in the two power cords.  Do not connect both cords to the same outlet.  The green, ‘separate  

 

circuit’ locator light (1) on the switch plate should light up. If the locator light does not come on,  

 

check the circuit breaker box in the wall, and/or try different outlets until it does turn on.  Although  

 

all systems in the machine may work correctly if you are not on two circuits, a circuit breaker in a wall  

 

panel may trip. If you make sure the green light is turned on, you will prevent tripped circuit breakers. 

6.  Prime the 1200 psi pump: fi ll the solution tank with water, if not already done, and turn on the pump.  

 

You may notice a ‘tone’ change in the sound of the pump (smoother, with less of a rattle).

 

CAUTION -- NEVER TURN ON THE SOLUTION PUMP BEFORE CONNECTING YOUR    

 

SOLUTION LINE TO YOUR MACHINE AND TO YOUR TOOL.  If the pump builds pressure  

 

before you connect the hose and tool,  you will not be able to connect them.

7.

 

Use defoamer to prevent foam.

8.  Attach the solution spray hose to the solution quick disconnect. Attach the vacuum hose to the hose  

 

barb on the front of the recovery tank.  Connect the other ends of the hoses to the tool.  

9.  Turn on the vacuum (2) and turn on the dump pump (3). Begin spraying.
10. When the job is fi nished, turn off the water source.  Vacuum the remaining solution from the solution  

 

tank into the recovery tank.

11. Run a few gallons of clean water through the system. Drain the recovery tank by opening the drain  

 

gate over a bucket or drain. Disconnect the hoses from the cleaning tool.

12. Unplug the power cords.
13. Clean the machine and the tool.  Never store your machine outside, and keep it from extremes in  

 temperatures.

Содержание MX 585

Страница 1: ...mer when foaming occurs to prevent vacuum motor damage 2 Connect the machine to a properly grounded outlet 3 Keep machine from rain snow and extremes in temperatures Store the machine in a heated loca...

Страница 2: ...0 F to the solution tank Do not use with damaged cord or plug If the machine is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service center Do n...

Страница 3: ...hine to break up any mineral or chemical build up that may have formed The vacuum motor and the pump do not require any scheduled main tenance however the motor may require replacement brushes after 1...

Страница 4: ...ng below and to Set Up and Operation instructions SWITCH PLATE Switches 12 Wheel Castor Recovery Tank Lid Vacuum Hose Connection Recovery Tank Drain Solution Tank Access Solution Output YOUR MACHINE M...

Страница 5: ...the two power cords Do not connect both cords to the same outlet The green separate circuit locator light 1 on the switch plate should light up If the locator light does not come on check the circuit...

Страница 6: ...tch panel on the top of the machine NOTE the dump pump is self priming You should see water start to flow within 30 seconds of the pump turning on If water does not begin to flow check the filter to s...

Страница 7: ...7 1 2 4 3 O O O 5 12 14 15 19 16 13 18 8 10 36 1 9 29 26 3 2 4 39 MX 585 Multi 220 240V 29 12 09 6 7 20 23 21 22 24 28 31 27 34 35 30 11 25 33 32 37 40 38 17 L A B E L...

Страница 8: ...EU 600758536 Power cord UK 20 600758569 Filter EMI Relay 21 600758570 Hinge pin kit 22 600758571 Wheel kit 23 600758572 Base compartment drilled 24 600758573 Castor kit 25 600758574 Latch and strike 2...

Страница 9: ...ugh Longer hose or larger diameter hose than standard Heat is not turned on No power in the wall outlet check to see if the breaker has tripped No power to the heat switch check wiring for opens No po...

Страница 10: ...Body Vacuum VAC Shutoff Waterlift Pump Heater Wand Weight Dimensions Lifetime Warranty One 3 stage Ball Float 28 KPa 83 Bar positive displacement adjustable 1600 W UK 2000 W EU Stainless steel single...