![Nilfisk-Advance MICROMATIC 13E Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/nilfisk-advance/micromatic-13e/micromatic-13e_service-manual_1693537021.webp)
RECOVERY WATER SYSTEM
SERVICE MANUAL
ENGLISH
Micromatic
TM
13E
9097511000(1)2008-04
19
RECOVERY SYSTEM CLEANING
Drive the machine to the appointed disposal area.
1.
Make sure that the power supply cable (10) is disconnected from the electrical mains.
2.
Lift the solution tank (14a) and, if necessary, drain it and clean it as shown in the User Manual.
3.
Open the transparent cover (A) and clean it with care.
4.
Clean the vacuum grid (B) with care.
Empty and clean the recovery tank (16) as shown in the User Manual.
5.
Check the transparent cover gasket (C) for integrity.
6.
NOTE
The gasket (C) creates vacuum in the tank that is necessary for vacuuming the recovery water.
If necessary replace the gasket (C) by removing it from the transparent cover (A).
Check that the seating surface (D) of the gasket (C) is integral and adequate for the gasket itself.
7.
Install the tanks and the transparent cover with vacuum grid.
8.
A
C
B
D
P100190