Nilfisk-Advance IVB 3-M Скачать руководство пользователя страница 5

03

english

IVB 3-M
IVB 5-M
IVB 7-M

1) 

Option depending on model

Precautions and safety regu-
lations when using the vacu-
um cleaner

Before start-up

Inspect power cord regularly 
to detect signs of damage, e.g. 
cracks or ageing.

If the power cord is damaged, 
it must be replaced by Nilfisk 
Advance Service or an electri-
cian to avoid danger before 
use of the vacuum cleaner is 
continued.

Use only the type of power 
cord specified in the operating 
manual.

Do not damage the power cord 
(e.g. by moving over it or pulling 
or crushing it).

Disconnect the power cord by 
pulling the plug only (do not pull 
or tug the power cord).

Inspect the vacuum cleaners to 
ensure that they are in proper 
condition. Plugs and couplings 
in power cords must at least 
have splash protection.

Never use the vacuum cleaner if 
the filter element is damaged.

Picking up liquids

If foam develops or liquid 
emerges, stop work immediately 
and empty the dirt tank.

Regularly clean the built in float 
(IVB 3-M) and level indicator 
hose (IVB 5-M/7-M) to limit the 
water level and check that they 
are not damaged.

See section 5 for information on 
handling liquids and (hazard-
ous) dust.

Electrical components

Check the rated voltage of the 
vacuum cleaner before con-
necting it to the mains supply 
system. Ensure that the voltage 
shown on the rating plate cor-
responds to the voltage of the 
local mains power supply.

If you are using an extension 
cord, use only those specified 
by the manufacturer or higher 
quality ones (see section 9.4 
„Technical data“).

It is recommended that the 
vacuum cleaner should be con-
nected via a residual current 
circuit breaker. This stops the 
supply of electricity if the leak-
age current to earth exceeds 30 
mA for 30 ms or it has an earth 
tester circuit.

When using an extension lead, 
check the minimum cross-sec-
tions of the cable:

Cable length
m

Cross section

<16 A

<25 A

up to 20 m

ø1.5mm²

ø2.5mm²

20 to 50 m

ø2.5mm²

ø4.0mm²

Arrange the electrical parts 
(sockets, plugs and couplings) 
and lay down the extension lead 
so that the protection class is 
maintained.

Never spray water on to the 
upper section of the vacuum 
cleaner. Danger for persons, 
risk or short-circuiting.

Observe the latest edition of the 
IEC regulations.

Dust Class M (medium). 
The dusts which belong 
to this class are: dusts 

with OEL values > 0.1 mg/m³ as 
well as saw dust. The machine is 

tested in its entirety by vacuums 
for this dust class. The maximum 
degree of permeability is 0.1% 
and the disposal must be low 
dust.

Содержание IVB 3-M

Страница 1: ...nwijzing Istruzioni sull uso Driftsinstruks Bruksanvisning Driftsvejledning K ytt ohje Navodilo za uporabo Uputstvo za rad Prev dzkov n vod Provozn n vod Instrukcja obs ugi Kezel si utas t s Instrucci...

Страница 2: ...IVB 3 M IVB 5 M IVB 7 M auto 1 4 3 5 6 7 3 11 9 8 10 IVB 3 M 14 auto 9 8 3 5 6 7 IVB 5 M 1 4 auto 14 IVB 7 M 2 3 4 1 5 5 6 8 10 12 12 13 10 9 14 auto auto...

Страница 3: ...2 3 Suction power control 6 4 3 Check volume flow monitor 6 4 4 Acoustic warning 7 4 5 Cleaning the filter element IVB 3 M 7 4 6 Cleaning the filter element IVB 5 M 7 M 7 5 1 Techniques 8 5 1 1 Picki...

Страница 4: ...rve recognized regulations for safety and proper use Do not use any unsafe work techniques Purpose and intended use The vacuum cleaners described in this operating manual are suitable for commercial u...

Страница 5: ...ard ous dust Electrical components Check the rated voltage of the vacuum cleaner before con necting it to the mains supply system Ensure that the voltage shown on the rating plate cor responds to the...

Страница 6: ...intenance staff or other persons In the maintenance area use filtered compulsory ven tilation wear protective clothing clean the maintenance are so that no harmful substanc es get into the surrounding...

Страница 7: ...er The mains plug should not be in serted into a socket 3 To pick up dust with maxi mum room concentration values Insert the filter bag into the dirt tank according to the instructions instructions in...

Страница 8: ...l panel To comply with regulations only ap proved dust producing tools should be connected The maximum power consumption of the connected power tool is stat ed in section 9 4 Technical data The hose d...

Страница 9: ...r removes attached dust from the slats of the filter elements To ensure that suction perform ance is always at its best the filter element is automatically cleaned during operation We recommend comple...

Страница 10: ...hygienic After picking up liquids the filter element is wet A damp filter el ement clogs more quickly when dry substances are picked up For this reason the filter element should be washed and dried o...

Страница 11: ...e foam killer Nilfisk Alto Foam Stop see section 9 5 Accesso ries for order number 6 After finishing work 6 1 Switching the vacuum cleaner off and storage 1 After picking up hazardous dust vacuum clea...

Страница 12: ...and remove the intermediate ring 2 from the tank 3 Carefully remove the waste bag connection from the inlet fitting 4 Close the waste bag using the cable binder 3 5 Dispose of the dirt in accordance...

Страница 13: ...he suction hose 5 Clean the inlet fitting and hose collar Only after picking up harmless dust without a filter bag 7 2 4 Emptying the dirt tank IVB 7 M 1 Remove the upper section of cleaner from the d...

Страница 14: ...it clockwise to secure it firmly 10 Dispose of the used filter ele ment in accordance with legal regulations Never use the vacuum cleaner without a filter During the following work ensure that dust is...

Страница 15: ...ad protection switch has tripped Switch off the vacuum cleaner and allow it to cool for approx 5 minutes If the cleaner can not be started again contact the Nilfisk Advance service department Self act...

Страница 16: ...9 3 Tests and approvals The vacuum cleaners have been tested as specified in IEC EN 60335 2 69 including appendix AA All the requirements were fulfilled for equipment in dust class M The vacuum clean...

Страница 17: ...0082 Filter screen 15475 Nilfisk Alto Foam Stop 6 x 1 l 8469 9 6 EC declaration of conformity 9 4 Technical data IVB 3 M 5 M 7 M EU GB 230 240V GB 110V EU GB 230 240V GB 110V EU GB 230 240V GB 110V Vo...

Страница 18: ...Nilfisk Advance A S Sognevej 25 DK 2605 Br ndby Denmark Tel 45 43 23 81 00 Fax 45 43 43 77 00 www nilfisk advance com...

Отзывы: