USER MANUAL
26
909 6752 000(2)2006-10 A
CHARGING THE BATTERIES
Preliminary operations
1.
Open the cover (22) and check that the recovery water tank (21) is empty, otherwise empty it with the drain hose (16).
2.
Drive the machine to the appointed recharging area.
3.
(Only for
BA 551 D
,
BA 551 CD
,
BA 611 D
): Turn the ignition key (80) to “0” position.
(Only for
BA 551
): Turn off the machine by pressing the switch (71) and/or (73).
4.
Grasp the handle (41) and carefully lift the tank (40).
5.
For WET batteries only:
–
Check the level of electrolyte inside the batteries (52); if necessary, top up through the caps (53).
–
Then leave all the caps (53) open for battery charging.
–
If necessary, clean the upper surface of the batteries.
6.
Charge the batteries according to one of the following procedures, depending on the presence of the battery charger (90).
Charging the batteries with an external battery charger
7.
Check that the external battery charger is suitable by referring to the relevant Manual. The battery charger voltage rating
must be 24 V.
8.
Disconnect the battery connector (12) and connect it to the external battery charger.
9.
Connect the battery charger to the electrical mains.
10.
After charging, disconnect the battery charger from the electrical mains and from the battery connector (12).
11.
(For WET batteries only) Check the level of electrolyte inside the batteries and close all the caps (53).
12.
Connect the battery connector (12) to the machine.
13.
Grasp the handle (41) and carefully lower the tank (40).
NOTE
Charge the batteries when the yellow or red warning light (81b or 81c) turns on, or at the end of every working
cycle.
CAUTION!
Keeping the batteries charged make their life last longer.
CAUTION!
When the batteries are discharged, charge them as soon as possible, as that condition makes their life
shorter. Check for battery charge at least once a week.
CAUTION!
If the machine is not equipped with on-board battery charger, choose an external battery charger suitable
for the type of batteries installed.
WARNING!
WET battery charging produces highly explosive hydrogen gas. Charge the batteries in well-ventilated areas
and away from naked flames. Do not smoke while charging the batteries.
Keep the tank assembly open while charging the batteries.
WARNING!
Pay careful attention when charging the batteries as there may be battery fluid leakages. The battery fluid is
corrosive. If it comes in contact with skin or eyes, rinse thoroughly with water and consult a physician.
Содержание ecoflex BA 551