23
D
Service / Repair.
Disassembly / assembly of the Pump
.
1.
In the bottom of the hole for the suction valve there is a guidance (rotation lock). The legs of
the suction valves MUST be placed on each side of this guidance (Fig 33)
2.
Before to assemble the pump, check that the suction valves are placed correct, by verifying
the level of the valves. One O-ring must be completely under the surface. (Fig 34)
Fig. 34
Fig. 33