Electrical System 136
Service Manual – CS7000
Maintenance and Adjustments
Charging the Battery (Battery Model)
See User Manual
Generator Drive Belt
The generator drive belt tension is maintained by an auto-tensioner and does not require adjustment.
Troubleshooting
42 volt generator is not charging
Potential Causes
• Broken or slipping drive belt - Check the drive belt
• No power to voltage regulator terminal - Check for battery voltage (36v) to the voltage regulator connector
• Open or corroded cable connections - visually inspect cable connections
• Generator/Regulator assembly
Insufficient machine operation time (Battery Model)
Potential Causes
• Battery is not fully charged
• Loose or corroded cable connections
• Battery
Insufficient machine operation time with engine off (Hybrid models)
Potential Causes
• Battery is not fully charged
• Loose or corroded cable connections
• Battery
Содержание CS7000 Fuel Cell EcoFlex
Страница 110: ...Electrical System 110 Service Manual CS7000 Electrical Panel Contactor Relay location Electrical Panel ...
Страница 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Страница 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Страница 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Страница 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Страница 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Страница 154: ...Service Manual CS7000 154 Electrical System 56509170 Rev L Sheet 8 of 9 Before SN 1000048160 Kubota LPG before LEV E4 ...
Страница 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Страница 172: ...Engine System LPG 172 Service Manual CS7000 Low LP Pressure Switch Fuel Tank Pressure relief valve Fuel Tank Area ...
Страница 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...