SOLUTION SYSTEM
61
Service Manual – Advenger, 2800ST, 3800ST, BR 755, BR 855
SOLUTION & AXP/EDS SYSTEM ERROR CODES AND MEASUREMENTS - ADVENGER / BR 755,
855 AND ST
Advenger /
BR 755, 855
Display
Error Code
ST Service
LED
Blink Code
Fault Description
Troubleshooting Action
8
1, 4
Solution solenoid overload
1. Check for a wiring problem.
2. Check coil resistance (see below).
3. Replace solenoid if coil is shorted.
11
NA
Chemical pump overload
1. Check for a wiring problem.
2. Replace pump.
30
2, 3
Visible in
Fault Recall
Mode
Solution solenoid open
1. Check for disconnected solenoid wiring plug, open in
wiring, or open in solenoid (see below).
2. Repair or replace.
Voltage at control board should be -24V referenced to B+.
37
NA
Chemical pump open
1. Check for disconnected plug or open in wiring.
2. Repair or replace
When the pump is On, it makes a clicking noise.
If the board output is correct it should appear as a pulsed
signal to a DVM.
62
4, 2
Solution solenoid control fault
1. If J3-11 is 24V referenced to B+ when Solution switch is
Off, replace control board.
2. If J3-11 is 0V referenced to B+ when Solution switch is Off,
disable fault via Hidden Menu. Refer to “Control Board J1,
J2, and J3 Pin Outs and Test Points” section.
Solution
Solenoid
Nominal
Resistance
Nominal Current
Overload Current
Wire Colors
L1
35 ohms
650 mA
750 mA
BRN & VIO/BLK
Chemical Pump
Nominal Current
Overload Current
Wire Colors
M2
PWM
870 mA PWM
n/a
Troubleshooting Solution & AXP/EDS System Issues
Problem
Possible Cause
Inadequate or no solution flow
No solution in the tank.
Red Solution Shutoff Valve (21) is in the Off position .
Clogged Solution Filter (20), valve L1, or hoses.
L1 Solution Solenoid Valve defect.
Main controller fault.
Advenger / BR 755, 855
Solution tank level indicator shows empty even
though the tank is full
Small clear hose at pressure sensor on control board is kinked - refer to “Replacing the
Operator Control Panel“ for instructions.
Solution flow and/or chemical rate don’t appear to
follow programming
1. Air leak at hose connection to pressure sensor.
2. Air leak at Pressure Sensing Tube fitting.
3. Small clear hose at pressure sensor on Interface Control Panel is kinked.
Solution level indicator doesn’t work after new
control board installed
1. Solution tank wasn’t completely drained before installation of new Interface Control
Panel. Completely drain the solution tank and the pressure differential should work
properly again.
2. Check for air leaks at re-connected hose fittings.
Chemical rate doesn’t match manufacturer
specifications
Check that pump is wired correctly and that the polarity isn’t reversed.
Содержание Advenger 2800ST
Страница 55: ...RECOVERY SYSTEM 55 Service Manual Advenger 2800ST 3800ST BR 755 BR 855 ST ...
Страница 62: ...SOLUTION SYSTEM 62 Service Manual Advenger 2800ST 3800ST BR 755 BR 855 Solution System Diagram FIGURE 28 ...
Страница 98: ...FORM NO 56043121 Advenger 2800ST 3400ST BR 755 BR 855 77 ELECTRICAL SYSTEM ...
Страница 101: ...80 FORM NO 56043121 Advenger 2800ST 3400ST BR 755 BR 855 Wiring Harness Diagram REV Deck 56601807 Revision A ...
Страница 104: ...FORM NO 56043121 Advenger 2800ST 3400ST BR 755 BR 855 83 ELECTRICAL SYSTEM ...