40 - Recovery System
87
Service Manual – SC250, Scrubtec 334, MA 30
Maintenance and Adjustments
Recovery Tank and Cover Cleaning
1 Lift the tanks container from the machine body
using the handle, and take it to the designated
disposal area
2 Drain the water from the tank
3 Remove the cover (A) clean and wash the cover
and the vacuum grid with water and detergent
(B)
4
If necessary, remove the grid body (C) and float,
than clean with care and reinstall
5 Check the recovery tank cover gasket (D) for
integrity
Note:
The gasket (D) creates the
vacuum in the tank that is
necessary to vacuum up the
recovery water.
6 If necessary, replace the gasket (D) by removing
it from its housing on the cover When
assembling the new gasket, install the joint (E)
in the area shown in the figure.
7 Check the air duct gasket (F) conditions If
necessary, replace the gasket
8 Clean the tank compartment (G) with water and
detergent, then rinse carefully
9 Check that the seating surface (H) of the gasket
(D) is clean and adequate for the gasket itself
10 Reassemble the components
Figure 4
A
H
B
F
C
E
D
G