188
Service Manual – SW5500, FLOORTEC R 985
29 - Engine System, LPG
Fuel Reserve sensor
WARNING:
This procedure must be performed by personnel qualified to handle the LPG systems,
according to the law in force.
Moreover, it is necessary to wear accident-prevention clothes, according to the law in
force (heavy gloves, antistatic non-synthetic clothes, suitable to cover the whole body,
antistatic and antispark shoes, helmets with visor; etc.).
Removal
in the relevant parapraph)
2
Drive the machine on a level floor.
3 Turn the ignition key to “0”, then engage the parking brake
4 Open the engine compartment hood with the handle and fasten it with the support rod
5
If fitted, remove the machine right side panel by lifting it to disengage it from the fasteners.
6 If the engine is hot, wait that it cools down
7 Disconnect the fuel reserve sensor (B) electrical connections (A)
8
Unscrew the fuel reserve sensor (B) while holding the fitting (C).
WARNING:
For removal / installation of the various hoses and fittings of the LPG system, see
in the relevant paragraph.
Assembly
9 Assemble the components in the reverse order of removal
10 Check the LPG system for leaks (see
in the relevant paragraph)
Figure 21:
C
A
B