Connections

If your amplifier has both “A” and “B”
speaker pair outputs connect the RSL-6
to the “A” outputs. Do not connect any-
thing to “B”. This will prevent the ampli-
fier or receiver from driving an unusual-
ly low impedance load.

Using the RSL-6 with Tube-Type
Amplifiers

Virtually all tube amplifiers must be
connected to a load at all times. If you
are using the RSL-6 with a tube-type
amplifier connect a 150 ohm, 5 watt
resistor across the tube amplifier’s out-
put in parallel with the RSL-6.

Impedance Matching

Use the 

SPEAKER

DIP switches on the rear

panel of the RSL-6 to tell the Micro-con-
troller the impedance of each speaker
pair. Then, set the 

AMP

DIP switches to

your amplifier’s recommended load (2,
4 or 8 ohms). This guarantees maximum
performance from your amplifier.

Interfacing with a Multi-Room
Infrared Repeater System

If you are using a Niles IR repeater sys-
tem to relay remote control commands
you may connect the 

FLASHER OUTPUT

or

OPTION OUT

of the repeater directly to the

IR DATA IN

on the rear of the RSL-6. If you

have an external sensor in the same
room as the RSL-6 you can avoid optical
feedback by disabling the front panel IR
sensor using the rear panel 

EYE

DIP

switch.

X-10 Interfacing

If you are using X-10 to control your
lights and you plan to control your RSL-6
with X-10, use the X-10 DIP switches to
assign the RSL-6 a starting code which
will not interfere with your lights.

MODEL RSL-6 Remote Controlled Speaker Selection System (continued)

NILES AUDIO CORPORATION

12331 S.W. 130 STREET   MIAMI, FLORIDA 33186   
TEL: (305) 238-4373   FAX: (305) 238-0185

CEDIA

CUSTOM
ELECTRONIC
DESIGN &
INSTALLATION
ASSOCIATION

CHARTER MEMBER

© 2000 Niles Audio Corporation.  X-10 is a registered trademark of X-10 (USA) Inc.  Note: Because Niles believes in constantly improving its products, Niles reserves the right to change product

specifications without notice. Printed in USA

APPLICATION NOTES

APPLICATION NOTES

IR DATA

IN

CONTROL

OUT

X-10

POWER

+  -

+  -

ALL ON
DEFEAT

UNIT

CODE

X-10

DEFAULTS

IMPEDANCE

AMP

SPEAKERS

8 OHM
4 OHM

START M

O

D

E

HOUSE

CODE

E

Y

E

L

R

AMPLIFIER

+

+

+

+

--

--

SPEAKER 5

SPEAKER 6

L

R

L

R

+

+

+

+

--

--

SPEAKER 3

SPEAKER 4

L

R

L

R

+

+

+

+

--

--

SPEAKER 1

SPEAKER 2

L

R

L

R

+

+

+

+

--

--

Niles Audio Corporation, Inc.

Miami, Florida  USA

NILES

MODEL RSL-6

Spring loaded push-

connector  for amplifier 

or receiver

EYE

DIP switch enables

you to disable the front

panel IR sensor.

X-10 DIP switches enable

you to select starting house

and unit codes.

SPEAKER IMPEDANCE

DIP switches enable

you to select proper
impedance for each

speaker pair.  

AMP IMPEDANCE

DIP switches

enable you to match the RSL-6

to your amplifier’s ideal load. 

CONTROL OUT

provides a 12V

DC output whenever one or

more speakers is turned on.

POWER

Jack for wall

adapter (included)

IR DATA IN

con-

nects to Niles IR

Repeater Systems

X-10 jack for TW-523

interface module.

ALL ON

DIP switches enable you to

select which rooms are activated

when the 

ALL ON

button is pressed.

Spring-loaded push connectors

for speakers 

TOOLS REQUIRED

• Wire stripper

• 1/8" standard slot-

ted screwdriver