Connections
If your amplifier has both “A” and “B”
speaker pair outputs connect the RSL-6
to the “A” outputs. Do not connect any-
thing to “B”. This will prevent the ampli-
fier or receiver from driving an unusual-
ly low impedance load.
Using the RSL-6 with Tube-Type
Amplifiers
Virtually all tube amplifiers must be
connected to a load at all times. If you
are using the RSL-6 with a tube-type
amplifier connect a 150 ohm, 5 watt
resistor across the tube amplifier’s out-
put in parallel with the RSL-6.
Impedance Matching
Use the
SPEAKER
DIP switches on the rear
panel of the RSL-6 to tell the Micro-con-
troller the impedance of each speaker
pair. Then, set the
AMP
DIP switches to
your amplifier’s recommended load (2,
4 or 8 ohms). This guarantees maximum
performance from your amplifier.
Interfacing with a Multi-Room
Infrared Repeater System
If you are using a Niles IR repeater sys-
tem to relay remote control commands
you may connect the
FLASHER OUTPUT
or
OPTION OUT
of the repeater directly to the
IR DATA IN
on the rear of the RSL-6. If you
have an external sensor in the same
room as the RSL-6 you can avoid optical
feedback by disabling the front panel IR
sensor using the rear panel
EYE
DIP
switch.
X-10 Interfacing
If you are using X-10 to control your
lights and you plan to control your RSL-6
with X-10, use the X-10 DIP switches to
assign the RSL-6 a starting code which
will not interfere with your lights.
MODEL RSL-6 Remote Controlled Speaker Selection System (continued)
NILES AUDIO CORPORATION
12331 S.W. 130 STREET MIAMI, FLORIDA 33186
TEL: (305) 238-4373 FAX: (305) 238-0185
CEDIA
CUSTOM
ELECTRONIC
DESIGN &
INSTALLATION
ASSOCIATION
CHARTER MEMBER
© 2000 Niles Audio Corporation. X-10 is a registered trademark of X-10 (USA) Inc. Note: Because Niles believes in constantly improving its products, Niles reserves the right to change product
specifications without notice. Printed in USA
APPLICATION NOTES
APPLICATION NOTES
IR DATA
IN
CONTROL
OUT
X-10
POWER
+ -
+ -
ALL ON
DEFEAT
UNIT
CODE
X-10
DEFAULTS
IMPEDANCE
AMP
SPEAKERS
8 OHM
4 OHM
START M
O
D
E
HOUSE
CODE
E
Y
E
L
R
AMPLIFIER
+
+
+
+
--
--
SPEAKER 5
SPEAKER 6
L
R
L
R
+
+
+
+
--
--
SPEAKER 3
SPEAKER 4
L
R
L
R
+
+
+
+
--
--
SPEAKER 1
SPEAKER 2
L
R
L
R
+
+
+
+
--
--
➡
➡
Niles Audio Corporation, Inc.
Miami, Florida USA
NILES
MODEL RSL-6
Spring loaded push-
connector for amplifier
or receiver
EYE
DIP switch enables
you to disable the front
panel IR sensor.
X-10 DIP switches enable
you to select starting house
and unit codes.
SPEAKER IMPEDANCE
DIP switches enable
you to select proper
impedance for each
speaker pair.
AMP IMPEDANCE
DIP switches
enable you to match the RSL-6
to your amplifier’s ideal load.
CONTROL OUT
provides a 12V
DC output whenever one or
more speakers is turned on.
POWER
Jack for wall
adapter (included)
IR DATA IN
con-
nects to Niles IR
Repeater Systems
X-10 jack for TW-523
interface module.
ALL ON
DIP switches enable you to
select which rooms are activated
when the
ALL ON
button is pressed.
Spring-loaded push connectors
for speakers
TOOLS REQUIRED
• Wire stripper
• 1/8" standard slot-
ted screwdriver