Nikon N Series/K Series Total Station Instruction Manual
91
Applications
4
Two-prism pole
1.
To enter the two-prism pole function, press
[3]
or
select
2Prism Pole
in the Offset menu.
2.
Sight the first prism and press
[MSR1]
or
[MSR2]
.
3.
Sight the second prism and press
[MSR1]
or
[MSR2]
.
4.
Enter the distance between the second prism and
the target point. Alternatively, if you do not need
QA information, you can leave the distance
between the first and the second prism blank.
5.
If you do enter a P1-P2 distance, the QA screen
appears. Compare the entered value and the
measured distance to check the accuracy of the
observation.
6.
To record the point, press
[ENT]
or the
OK
softkey.
Sample records
SS,14,0.0000,38.9200,271.0350,89.2630,11:04:15,DITCH
CO,2Prism O/S: P1-P2= 0.5090( 0.5060) P2-Tgt= 0.5020
Note –
In this sample data, 0.5090 is the measured value. 0.5060 is the entered value.
Содержание K Series
Страница 1: ...www trimble com Part Number C325E1 January 2020 N Series K Series Total Station Instruction Manual ...
Страница 2: ......
Страница 12: ...Safety xii Nikon N Series K Series Total Station Instruction Manual ...
Страница 18: ...Contents xviii Nikon N Series K Series Total Station Instruction Manual ...
Страница 70: ...3 Getting Started 52 Nikon N Series K Series Total Station Instruction Manual ...
Страница 162: ...5 Menu Key 144 Nikon N Series K Series Total Station Instruction Manual ...
Страница 168: ...6 Checking and Adjustment 150 Nikon N Series K Series Total Station Instruction Manual ...
Страница 172: ...7 System Diagrams 154 Nikon N Series K Series Total Station Instruction Manual ...
Страница 188: ...8 Communications 170 Nikon N Series K Series Total Station Instruction Manual ...