FCA54001-R.3567.A
- R3 • One Touch Zoom 90s AF -
Item
Standard of judgment
Method and tools
Lens barrel
unit
Eccentricity
·The clearance between the lens barrel and front
cover must be 1/2 or less of the difference
between the maximum and minimum parts.
Check the clearance between the lens barrel and
front cover.
Pin gauge
Driving noise
·It must be 58dB or less at average sound
pressure.Abnormal noise must not occur during
operation.Measure noise in 45° at a position
20cm away from the lens front surface.
Lens barrel abnormal
stop
·There must be 400g or more in the upward
position.Set the lens barrel upward and put a
special gauge on it.
Special gauge
Automatic
exposure
AE accuracy
AE tester
Power supply(1)
·The camera must meet the following
conditions in ISO100, 200, 400 and 800.
·Unexposed photography must not occur.
Application range A
WIDE: 6 ≦ Ev ≦ 15.0
TELE: 6 ≦ Ev ≦ 17.0
Error: +2.0 ~ -1.0Ev
Difference: 1.5Ev
Neighboring difference: Reverse must not occur
every 1.5Ev.
Application range B
WIDE: 15.0<Ev ≦ 16.0
TELE: 17.0<Ev ≦ 18.0
Error: +2.5 ~ -1.5Ev
Difference: 2.0Ev
Neighboring difference: Reverse must not occur
every 2.0Ev.
Error: Error of each measured value obtained by
continuous 3 measuring operations
Difference: Difference between the maximum and
minimum values obtained by continuous 3 measur-
ing operations
Neighboring difference: Average value obtained
by measuring the neighboring exposure values 3
times continuously
FM accuracy
Application range A: 4.94 ≦ F ≦ 11.31
Error: +2.0 ~ -1.0Av
Difference: 1.5Av
Neighboring difference: Reverse must not occur
every 1.5Av.
Application range B: 11.31 ≦ F ≦ 16.00
Error: +2.3 ~ -1.3Av
Difference: 1.8Av
Neighboring difference: Reverse must not occur
every 1.8Av.
AE tester
Power supply(1)
Speed light
Guide number
·Gno.: 10 (ISO100·m)±0.5Ev
·Point and line: Gno.7.1 or more
Measure the guide number at a position
1.97m away from the speed light whole
surface. (From film surface: 2m)
JC II flash
Meter IV
Power supply(1)
Light division
characteristics
·At 28° in the right and left direction
and 20° in the up and down direction,
within -1Ev against the image center
JC II flash
Meter IV
Power supply(1)
Recycling time
·8 seconds or less
Release occurs after 8 seconds since winding
ended.
Power supply(1)
Stop watch
Содержание FCA54001
Страница 10: ...FCA54001 R 3567 A M8 One Touch Zoom 90s AF AE coupling graph WIDE Coupling range A Coupling range B ISO value ...
Страница 11: ...FCA54001 R 3567 A M9 One Touch Zoom 90s AF AE coupling graph TELE Coupling range A Coupling range B ISO value ...
Страница 48: ...FCA54001 R 3567 A E4 One Touch Zoom 90s AF ...
Страница 49: ...FCA54001 R 3567 A E5 One Touch Zoom 90s AF ...
Страница 50: ...FCA54001 R 3567 A One Touch Zoom 90s AF INSPECTION STANDARD AND TOOLS 1 Inspection standard R1 2 Tools T1 ...