background image

 

 
 
 
 
 

Please read the safety instructions before using the 
device. Read this Quick Setup Guide for the correct setup 
and installation. 

 

 
 

Technical data of the equipment and general safety:

 

 

Mains connection 
 
Voltage: 

100VAC to 240VAC 50/60 Hz 

Eletrical Safety:  

CE conformity 

 

 

Climatic conditions 
 
ONLY use in dry rooms! 
Temperature: 0 to max. 40 °C 
Operating humidity: 0% bis 80 % r.F, non-condensing 
Operating altitude: 0 to 2000m above sea level 
 
 
Additional Safety Information:

 

o

 

Place the appliance on a flat, stable, and vibration-free surface such as a desk. Choose a dry, 
well-ventilated area out of direct sunlight. Do not place the device on a carpet to protect it 
from dust. 

o

 

DO NOT place objects on the device . 

o

 

DO NOT slide in any objects through the slots of the device 
They may touch dangerous current carrying parts or cause a short circuit and resulting in a 
fire or electric shock. 
If objects made of metal, water or other liquids get into the unit, unplug the power cord 
immediately. 

INSTALLATION MANUAL 

rev. 1.1

 

Vizoo xTex  

Содержание D5200

Страница 1: ...2000m above sea level Additional Safety Information o Place the appliance on a flat stable and vibration free surface such as a desk Choose a dry well ventilated area out of direct sunlight Do not place the device on a carpet to protect it from dust o DO NOT place objects on the device o DO NOT slide in any objects through the slots of the device They may touch dangerous current carrying parts or ...

Страница 2: ...hours always switch the device off using the main power switch Repair Product liability and Warranty Service Do not attempt to repair this product yourself as opening or removing covers may expose you to dangerous current carrying parts and other risks and may void your warranty For repair service please contact the support support vizoo3d com Do not use the unit in a humid environment or near wat...

Страница 3: ...ple Reset the unit carefully and be careful to not pinch your fingers For packaging plastic bags and other packaging elements made of plastic were used Keep them out of reach from babies and children to prevent suffocation Housing Camera Nikon D5200 Nikon D800 Nikon D810 or Nikon D850 Lens model might differ from image ...

Страница 4: ...e Download link https customers vizoo3d com manual_d5200_en https customers vizoo3d com manual_d800_en https customers vizoo3d com manual_d810_en https customers vizoo3d com manual_d850_en Camera Mount Power cable Inlet connector USB Connector cable to PC ...

Страница 5: ...5 Camera Power Adapter Nikon EP 5A or Nikon EP 5B can be pre installed Camera Screw with or without seal Fixing Screw for Camera Mount Calibration chart model might differ from image ...

Страница 6: ...6 2 Device Overview Power indication light Pullout Capturing surface Camera mount guide Pullout open Device housing Lens bracket ...

Страница 7: ...7 Power supply camera USB port camera USB port PC Main Power switch on off Mains connection Electronics ...

Страница 8: ...sing Make sure that the shorter side of the bracket is in the guide Then turn the fixing screw into the thread of the guide Tighten the screw slightly so that the camera position can still be moved in the guide Then set the camera screw into the hole provided on the longer side of the camera mount ...

Страница 9: ...camera to the opening of the lens bracket with the lens facing down and the rear display facing up For this and the following steps make sure to always keep at least one hand on the camera lens Make sure that the camera is sitting on the lens bracket with its full weight and is covering the opening completely Slide the camera mount close to the bottom of the camera Now move the camera screw in the...

Страница 10: ...e USB port of the device Connect the camera power cable Connect one end to the plug of the power connector and insert the special connector to the jack of the device s camera power supply The special connector has 4 pins and a groove at the bottom Insert the plug fully into the socket first and then turn the knurled bezel clockwise Connect the USB connector cable to the PC Connect the end of the c...

Страница 11: ...lens model The switch for the image stabilizer is sitting on the side of the lens Set it to OFF Set the focus mode of the camera lens to autofocus Nikon D5200 only Switch the A M switch of the lens Autofocus man Focus to A Nikon D800 D810 D850 only Switch the A M switch of the camera to AF ...

Страница 12: ...on the front of the device should now be light green Turn on the camera Start the xTex software on the computer that is connected to the device Focus the camera Follow the instructions of the software documentation to start Focus Calibration Calibrate colors Follow the instructions of the software documentation to start Color Calibration ...

Страница 13: ...ection 6 whenever you change the device setup e g by removing the camera changing the lens or using the zoom ring of the lens not available on all models Focus Calibration Use Focus Calibration whenever you feel the captures are getting blurry Color Calibration It is advisable to periodically repeat Color Calibration about every 4 6 weeks ...

Страница 14: ...14 ...

Страница 15: ...15 2017 Printed in Germany Vizoo GmbH Johann Karg Str 30 85540 Haar ...