JAA80251-R.3723.A
- A 24・AF-S 24-70/2.8G -
CH1
CH2
CH1
CH2
C H 1 = 1 0 0 m V C H 2 = 1 0 0 m V 5 0 0 μ s / d i v
A C 1 0 : 1 A C 1 0 : 1
NORM
C H 1 = 1 0 0 m V C H 2 = 1 0 0 m V 5 0 0 μ s / d i v
A C 1 0 : 1 A C 1 0 : 1
NORM
Fig.1
Fig.2
<
Ref.
>
● As shown in Fig. 1,
if the amplitude of only either CH1 or CH2 is small, one of the 2 screws (#119)
may be loosened, so check for it. If this is not the case, the GMR sensor may malfunction so
replace it and make a readjustment.
●
As shown in Fig. 2, if the amplitude partially drops during the rotation, the magnetic data of the
tape of the focus turning-tube unit may be damaged. So replace the focus turning-tube unit and
make a readjustment.