2.3. Connection
Danger:
Do not install the two-channel transmitter while it is connected to the mains voltage supply. Do not connect the device to the mains voltage until
installation is complete.
1. Switch off the mains supply.
2. Mount the two-channel transmitter in the flush-mounting box.
3. Select the desired operation mode by placing the jumper between the L and F terminals. The two-channel transmitter is supplied with switching function
(jumper J installed). You can also choose the push button function or the roll-down shutter push button function. In both cases, the jumper (J) is not placed.
4. Connect the power supply and the switch or push button as shown in the wiring diagram below, dependent on the selected operation mode:
A. Switch function
The jumper (J) has been placed. When the state of the switch is changed, the two-channel transmitter
sends a switching command during approximately 0.5 s.
Switch 1: input S1
Switch 2: input S2
Code A: close switch
Code B: open switch
Code C: close switch
Code D: open switch
B. Push button function
The jumper (J) has not been placed. The two-channel transmitter sends a switching command as
long as the push button is held down, for up to 10 s. The inputs cannot be switched simultaneously.
Push button 1
input S1 – code A
Push button 2
input S2 – code B
C. Roll-down shutter push button function
The jumper (J) has not been placed. The two-channel transmitter sends a switching command as
long as the push button is held down, for up to 36 s. The inputs cannot be switched simultaneously.
Push button 1
input S1 – code A
Push button 2
input S2 – code B
5. Finish with a blind plate.
6. Switch on the mains supply.
7. Program the two-channel transmitter on the chosen wireless receiver according to the Easywave protocol (see manual of the receiver).
If you control the switch or push button now, the two-channel transmitter sends the corresponding switching command to the receiver.
2.4. Remote programming (*)
With this function, you active the remote programming mode for receivers which have already been connected to the transmitter. This function is activated by
moving the jumper into the correct position (A, B, C, D, see § 2.3) and shortly pressing the programming button (see § 1).
To do so, follow the instructions in the diagram below:
With jumper
Without jumper
S1
Code A
S1
Code C
S2
Code B
S2
Code D
Read the receiver manual before activating this function.
(*) Not every receiver is suitable for this function.
S2
S1
N
230 V
L
L
Rxx / xxxxxxx / YYWWD25
868,3 MHz
230 V AC 50 Hz
0,43 W 50 mA
N L
prog.
F
2
S
1
S
410-00362
S1
S2
N
230 V
L
L
Rxx / xxxxxxx / YYWWD25
868,3 MHz
230 V AC 50 Hz
0,43 W 50 mA
N L
prog.
F
2
S
1
S
410-00362
L
S1
S2
N
230 V
L
L
Rxx / xxxxxxx / YYWWD25
868,3 MHz
230 V AC 50 Hz
0,43 W 50 mA
N L
prog.
F
2
S
1
S
410-00362
L