350-30010 350-20011
350-20010 390-20010
30
6. PRODUCT MAINTENANCE
A dirty lens affects the operation of the sensor. The sensor’s lens
has to be kept clean. Use a damp cloth for cleaning. Use water
mixed with ordinary detergent. Avoid pressing hard on the lens on
the front panel. If the lens or other parts of the sensor are defective,
it/they have to be replaced.
7. TECHNICAL DATA
Supply voltage ....................... 24V DC ±10%
Power consumption:
............................................. Max. <5mA (24V DC)
............................................. Standby <3mA (24V DC)
............................................. Max. current load <50mA (24V DC)
Output contact ....................... ON/OFF, NPN
Lux sensitivity (lux)
350-30010: ......................... 3-300lx
Range:
350-20010/350-30010: ....... 90°, 0.5...15m
350-20011: .......................... 90°, 0.5…8m (width 1m)
Impact resistance ................... IP20
With cap 390-20010 ............ IP54
Ambient temp. ....................... -20 to 50°C
Cable dimension .................... 3 x 0,6mm diameter
ENG
Содержание 350-20010
Страница 8: ...350 30010 350 20011 350 20010 390 20010 8 NL...
Страница 16: ...350 30010 350 20011 350 20010 390 20010 16 FR...
Страница 24: ...350 30010 350 20011 350 20010 390 20010 24...
Страница 32: ...350 30010 350 20011 350 20010 390 20010 32 67 52 34 109 69 56 41 390 20010...
Страница 33: ...350 30010 350 20011 350 20010 390 20010 33 350 20010 350 20010 350 20010 350 20011...
Страница 35: ...350 30010 350 20011 350 20010 390 20010 35 350 20010 350 20011...