![Niko 10-901 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/niko/10-901/10-901_manual_1689565019.webp)
19
10-901
You can connect more code keyboards to the power supply than can actually be control-
led simultaneously. See the table below for the choice of the power supply.
Power supply
Max. number of
10-901
Max. number of 10-901
simultaneously controllable
10-801: I(P) = 60mA
3
1
10-802: I(P) = 100mA
5
2
10-806: I(P) = 600mA
30
10
10-801 + 10-805-01: I(P) = 2,5A
64
32
Use as stand-alone appliance
You can use the code keyboard as a stand-alone appliance. Connect a 24VDC power sup-
ply (60mA) between terminal b (=mass) and P. To control the door lock, you can connect
a 24VDC relay (10-835) between terminal R and P. You can only use the R contact (see
‘programming’). In order to power the door contact, you need an additional power supply
(for the cabling, see fig. 3b
Fig.3b: wiring diagram: keyboard as stand-alone appliance
If everything has been connected correctly and the front is back in place, the 5 blue LED’s
of the code keyboard light.
EN
230V~
a b R P
L N
- +
10-901
Relais
10-835
24V