EN
38
10-35x
8.3. Mounting of the sealing of the front plate
First, use a knife to make the front plate's horizontal seal max.
2 mm shorter than the horizontal edge of the front plate.
After, make the two vertical seals max. 11 mm shorter than
the vertical edges of the front plate.
Keep a distance of max. 1 mm from the edge of
the front plate.
Stick the front plate's horizontal seal onto the back of the front
plate (image 6).
Always stick the vertical seals of the front plate from one end to
the other onto the horizontal seals (detail image 6).
The lower edge of the front plate can not be
sealed. Possible condensation water must be
able to flow away unhindered.
1x horizontal seal
of the front plate
2x vertical seal
of the front plate
Image 6: front plate (back view)
8.4. Mounting of the front plate
Place the front plate's guide plates onto the flush-mounting
cassette's bolts.
Mount the guide plates using the nuts (M3). Do not completely
tighten the nuts yet.
Crookedly placed flush-mounting cassettes
can be adjusted onto the guide plates with a
maximum tolerance up to 15 mm deep.
Slide the guide plates with the front plate into the housing, until
the curved edges only just touch the plastering.
Tighten the nuts (M3).
Close the external unit.
Tighten the front plate using the countersunk screws (M4x30).
Partition
Curved edge
Guide plate
Front plate
Flush-mounting
cassette
Image 7: Aligning the guide plates Image 8: Aligning on the plastering
9. CONNECTION OF THE MODULE
9.1. Connecting wires
• The modules may only be used on safety extra-low voltage (SELV) and protective extra-low voltage (PELV).
• Only use connection wires from the same material and with the same diameter in a terminal contact.
10. INITIAL ACTIVATION
Only install the devices of the installation when disconnected from the main voltage.
Ensure the installation is completely connected. Mount all components.
In turn, check a-, b- and P-conductor against each other for short circuits.
Switch on the mains voltage.