nv
Niko
sa Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — e-mail: [email protected] — www.niko.be
PM005-00202R15342
05-002-02
LED indications:
(A)
4 for outputs
(B)
1 for Nikobus
(C)
1 for power supply of the switching unit
(D) Programming key:
set by using a screwdriver
(E) Output selection key:
to choose 1 of the 4 outputs
(F)
Mode selection key:
to choose 1 of the 14 modes
(G)
Time switch:
to set the time
(H) Bus connection
(I) Display of set mode
Audio signal:
short signals: programming mode
long signal: recognizing sensor
double short signal: delete
A
B
H
G
F
I
E
C
LOADS
FUSES
230 V~
NIKOBUS PUSH BUTTONS
MODULE 1
MODULE 2
MODULE 3
DISTRIBUTION BOARD
LOADS
FUSES
230 V~
NIKOBUS PUSH BUTTONS
MODULE 4
MODULE 3
DISTRIBUTION BOARD 2
LOADS
FUSES
NIKOBUS PUSH BUTTONS
MODULE 2
MODULE 1
DISTRIBUTION BOARD 1
D
OUTPUTS, e.g. light points
Max.
10A
NIKOBUS PUSH BUTTONS
and INTERFACES
IR
RF
10A
230V~
L
N
16A
Max.
10A
Max.
10A
Max.
10A
fig.1
fig.2