background image

mm

FUNCTION SETUP

mm

1

mm

mm

TOL

1

mm

1

mm

TOL INPUT

1

mm

TOL INPUT

1

TOL

mm

1

PRESET

INPUT

mm

1

mm

1

mm

 This option

  not used

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

Measurement Display

Press the [MODE] Button, or Press-and-hold, to access and cycle through the functions 
as show in the chart below. When the function is displayed, press Center Button to access.

If no operation is performed after 5 seconds, display will return to measurement screen.

[MODE] Button

[MODE] Button

[MODE] Button

[MODE] Button

Long Press

[MODE] Button

Return to 
Measurement Display

REF1 / REF2 Mode

Two different Zero points, REF1 and REF2 can 
be used (also Tolerance settings.) This feature is 
helpful when there are multiple measurement 
criteria in use at the same time.

Preset Value

Any number can be preset for use in setting display 
during measurement by using this function.

Press [SET] in measurement screen to set display 
the preset value.

Press Center Button for numeric display. Press 
Center Button to move the cursor, and [SET] to 
change the value of that character. Press [Mode] to 
enter.

To Set

Press Center Button to display REF1 / REF2, then 
press [SET] to select.

To Set

Center Button can be programmed to call up a frequently used 
function with a single press while taking measurements.

Programmed setting is reset when power is turned off.

Programmable 

Favorite

 Button

Press and hold the Center 

Favorite

 Button to enter the button 

programming selection mode.Press Center Button to cycle through the 
options and then press [MODE] or [SET] to select.

To Set

Long Press

Center Button

This option 

not used

This option 

not used

Hold function

Reset MIN, 

MAX, DELTA 

display

Zero setting

Switch 

REF1 / REF2

Center Button

Center Button

Center Button

Center Button

Center Button

Center Button

Center Button

Center Button

Center Button

Center Button

Center Button

Center Button

Preset

NOR, MIN, 

MAX, DELTA 

mode

Tolerance 

Setting function 

ON / OFF

Resolution setting 

0.001 / 0.0001

Measurement 

Direction 

 / 

Calculation

function

Set to 1.000

to disable




This is a precision instrument, handle with care. Do not drop or subject 
to excessive forces.
Keep away form high voltage and strong magnetic fields; instrument 
damage may result.
Do not use or store in direct sunlight or locations with high 
temperatures such as in a car, or near a stove or heat source.
When taking measurements, hold gauge securely, such as in 
magnetic base. (sold separately)
Please do not disassemble or modify.
Remove dust and cutting chips after use and apply rust preventative 
oil to metallic surfaces. Please keep out of reach of children.
Do not use organic solvents to clean the body of the instrument.
When not being used for a long period of time, please remove battery. 
Only use as directed. Improper use may cause accident or injury.

CAUTION

I303-K

1606

Niigata seiki Co., Ltd.

6-15-22, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-31-5670   Fax. : +81-256-39-7730

MAIL   [email protected]

URL    http://www.niigataseiki.co.jp

Display Mode

Press Center Button 
to move the cursor, 
and [SET] to change 
the value of that 
character. Press 

[Mode] to enter.

Tolerance Function

With tolerance values set, gauge will show if 
measurement is within range.
Colored lights will show tolerance determination 
for easy judgment.

To reverse the display indication, reverse the entry of the Lower and 

Upper limits.

Measurement Direction

mm

mm

Calculation Function

You can enter a number to multiply by the 
amount of Spindle movement.

mm

Auto Off

mm

Button Lock

For locking buttons while taking measurements. 

mm

When lock is ON, 

『  』

icon will display on LCD.

To release the lock mode, press and hold [SET] 
until 

              

 is displayed.

Ex: If computation factor is set to 

2.00", and measured value is 

4.25

 

(actual amount of Spindle motion,) the displayed reading will be 

8.50

Set Lower

 Limit

Set Upper

 Limit

For measurement Lower limit set to 

+3

, Upper limit set to 

+6

Measurement: 2. 25mm

Red Light

Measurement: 4. 00mm Measurement: 7. 25mm

Measurement: 7. 25mm

Orange Light

Ex:

Green Light

OK

For measurement Lower limit set to 

+6

, Upper limit set to 

+3

Red Light

Measurement: 4. 00mm

Measurement: 2. 25mm

Orange Light

Ex:

Green Light

OK

Set measurement mode: 

(MIN),

(MAX), 

(MINMAX),or 

 (NORMAL)

※“

deltA

 (MINMAX)

Display maximum displacement without regard to direction (TIR).

[MODE] Button

[MODE] Button

[MODE] Button

[MODE] Button

[MODE] Button

[MODE] Button

[MODE] Button

[MODE] Button

[MODE] Button

Center Button

Center Button

Press Center Button to display options, then press 

[SET] to select.

To Set

Resolution

Press Center Button to display 0.001 / 0.0001, 
then press [SET] to select.

To Set

Press Center Button to display ON / OFF, then 
press [SET] to select.

To Set

Press Center Button to move the cursor, and [SET] 
to change the value of that character. Press [Mode] 
to enter.

To Set

Press Center Button to display 

 / 

 

and press [SET] to select.

        

』…

disabled  

           

』…

Auto off if idle for 20 min.

To Set

Press Center Button to display  (

) /  (

), then 

press [SET] to select.

To Set

Tolerance values can be set for MIN,

MAX, and DELTA modes.