background image

Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • USA • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com

INS-XPR-5580-17

9-19-2017

Instruction Manual

XPR-5580G/R

THANK YOU FOR SELECTING THE NIGHTSTICK XPR-5580 

INTRINSICALLY SAFE RECHARGEABLE MULTI-FUNCTION DUAL-

LIGHT LANTERN!

PLEASE SAVE THESE INSTRUCTIONS 

Please read these instructions before using your Nightstick XPR-5580 

They include important safety information and operating instructions.

THE XPR-5580 IS APPROVED FOR USE 

WARNINGS - INTRINSICALLY SAFE

 

y

Warning: To prevent ignition of a hazardous atmosphere, do not locate 

the charger for this product in the hazardous environment.  The charger for 

this product must be located in an area known to be non-hazardous ONLY.

 

y

Warning: To prevent ignition of a hazardous atmosphere, do not attempt 

to charge this product in the hazardous environment.  This task must ONLY 

be performed in an area known to be non-hazardous.

 

y

Warning: Lithium-ion batteries must be used and charged properly. 

Improper use can result in serious injury, fire, or death.

 

y

Warning: Use only the included and approved 5580-BATT rechargeable 

battery pack from Bayco Products.

 

y

Warning: Do NOT attempt to use any other rechargeable or non-

rechargeable batteries with this light.

 

y

Warning: To prevent ignition of a hazardous atmosphere, do not open 

the lens bezel in the hazardous environment.  This task must ONLY be 

performed in an area known to be non-hazardous.

 

y

Warning: When exchanging the rechargeable battery pack, use only the 

approved 5580-BATT rechargeable battery pack from Bayco Products.

 

y

Warning: To prevent ignition of a hazardous atmosphere, the rechargeable 

battery pack must only be exchanged in an area known to be non-hazardous.

 

y

Warning: Do not expose the rechargeable battery pack to water or salt 

water, or allow the battery pack to get wet.

 

y

Warning: Do not store the rechargeable battery pack with metallic objects 

that may cause a short circuit.

 

y

Warning: Substitution of components may impair intrinsic safety.

SPECIAL INSTRUCTIONS FOR INTRINSIC SAFETY

 

y

For personal safety, always confirm the rating of any known hazardous or 

potentially hazardous location where the light is to be used.

INITIAL USE

Warning: To prevent ignition of a hazardous atmosphere, do not attempt 

to charge this product in the hazardous environment.  This task must 

ONLY be performed in an area known to be non-hazardous.

CLASS I DIV 1 GRPS A-D T4
CLASS II & III DIV 1 GRPS E-G
CLASS I ZONE 0 GRP IIC T4
CLASS II ZONE 20 IIIC T135ºC

Ex ia IIC T4 Ga
DEMKO 16 ATEX 1796
IECEx UL 16.0154
-20ºC ≤ Tamb ≤ +40ºC
3.7V/Cell 5500-BATT
U

m

 = 4.75V

0359

E 467756

INTRINSICALLY SAFE

SECURITE INTRINSEQUE

II 1 G Ex ia IIC T4 Ga

Bayco Products, Inc.     XPR-5580

Ex ia FLASHLIGHT FOR USE IN HAZARDOUS LOCATIONS

UL listed for use with Bayco Li-ion Battery Pack 5500-BATT 

Wylie, TX  75098

ID 400184

Fully charge the XPR-5580 before the first use, or if the battery is new or 

has been unused for several months. The maximum charge time required is 

approximately 6 hours.

DAILY USE

WARNING: TO PREVENT IGNITION OF A HAZARDOUS ATMOSPHERE, 

DO NOT ATTEMPT TO CHARGE THIS PRODUCT IN THE HAZARDOUS 

ENVIRONMENT.  THIS TASK MUST ONLY BE PERFORMED IN AN AREA 

KNOWN TO BE NON-HAZARDOUS.

 

y

Use only the supplied Nightstick charger, 5580-BATT rechargeable 

battery pack and AC or DC adapter. For best performance, charge the 5580 

when the flashlight beam starts to dim.

 

y

Connect the AC power adapter to the charger. The LED indicator will not 

be illuminated at this point.

 

y

With the flashlight facing forward, slide the 5580 into the charger until the 

contacts snap into place.

 

y

The LED indicator changes to constant red indicating the 5580 is properly 

inserted into the charger and is in fact charging. The LED indicator remains red 

until the battery is fully charged. At full charge, the LED indicator turns green. 

 

y

The total time to full charge the 5580 varies depending on the remaining 

charge in the battery pack.

 

y

To  confirm  a  full  charge,  keep  the  5580  in  the  charger  and  turn  it  on. 

The LED indicator will change to red. Turn off the 5580. If the 5580 is fully 

charged, the LED indicator will turn green. If not, it remains red until the 

charge is completed and the LED indicator turns green. The 5580 will now 

be fully charged.

REPLACING LITHIUM-ION RECHARGEABLE BATTERY

While it is highly unlikely that the Lithium-ion Rechargeable Battery Pack 

for the XPR-5580 will ever need replacement, the product is designed to 

allow the end user to replace it if needed.  To replace the rechargeable battery 

pack, carefully follow the instructions listed below:

WARNING: TO PREVENT IGNITION OF A HAZARDOUS ATMOSPHERE, 

DO NOT OPEN THE LENS BEZEL IN THE HAZARDOUS ENVIRONMENT.  

THIS TASK MUST ONLY BE PERFORMED IN AN AREA KNOWN TO BE 

NON-HAZARDOUS.
WARNING: WHEN EXCHANGING THE RECHARGEABLE BATTERY 

PACK, USE ONLY THE APPROVED 5580-BATT RECHARGEABLE 

BATTERY PACK FROM BAYCO PRODUCTS.
WARNING: TO PREVENT IGNITION OF A HAZARDOUS ATMOSPHERE, 

THE RECHARGEABLE BATTERY PACK MUST ONLY BE EXCHANGED 

IN AN AREA KNOWN TO BE NON-HAZARDOUS.

 

y

Carefully loosen the center plug located on the rear side of the light with a 

flat head screw driver or small coin in a counter-clockwise direction.

 

y

Slowly turn the light upside down and carefully shake the light in order 

to allow the 5580-BATT rechargeable battery pack to slide out of the light 

paying close attention to the battery pack’s orientation within the housing.

 

y

Using only the approved replacement 5580-BATT rechargeable battery 

pack from Bayco Products, slide the new battery pack into the housing of 

the light using the directional arrow marked on the side of the pack to be a 

guide to proper battery orientation.

 

y

Carefully tighten the plug with a flat head screw driver or small coin until 

it is fully seated.  CAUTION:  Do NOT overtighten the plug.  Doing so may 

damage the threads and impair the light’s ability to properly charge and 

impact the light’s Intrinsic Safety.

OPERATION 

The  XPR-5580  has  ten  lighting  modes:  constant-on  flashlight,  full 

brightness  flashlight,  low  brightness  flashlight,  survival  mode,  floodlight, 

full  brightness  floodlight,  low  brightness  floodlight,  survival  mode,  blinking 

floodlight, dual-light mode, and constant-on or blinking rear facing lights. The 

XPR-5580 has two body switches providing access to all modes.
Constant-on Flashlight

Press the left body switch forward for full-brightness flashlight. Press the 

switch forward again to turn the light off.
Select Brightness Level

Press and hold the left body switch forward. The flashlight will cycle from 

high to low to survival mode and then back up again at a rate of approximately 

one mode per second. The light will continue to cycle up and down through 

Отзывы: