background image

 HR Series 

Operating & Safety Instructions 

 
English/USA – 11/06 

2 Safety 

2.1 MANDATORY 

PRECAUTIONS 

When operating your Niftylift, your safety is of utmost concern.  In order to fully appreciate all aspects 
of the machines operation it should be ensured that each operator has 

READ

 and fully 

UNDERSTOOD

 

the relevant manual covering machine use, maintenance and servicing. If any doubts exist concerning 
any points covered in your manual, contact your local dealer or Niftylift Ltd. 

Before using any Niftylift, thoroughly inspect the machine for damage or deformation to all major 
components.  Likewise, check the control systems for hydraulic leaks, damaged hoses, cable faults or 
loose covers to electrical components. At no time should damaged or faulty equipment be used - 
Correct all defects before putting the platform to work. If in doubt, contact your local dealer or Niftylift 
Ltd (see front cover for address). 

THE MANUFACTURER HAS NO DIRECT CONTROL OVER THE MACHINE 
APPLICATION AND USE. THEREFORE CONFORMATION WITH GOOD SAFETY 
PRACTICES IS THE RESPONSIBILITY OF THE USER AND HIS OPERATING 
PERSONNEL.  FAILURE TO UNDERSTAND AND FOLLOW ALL SAFETY RULES 
COULD RESULT IN SERIOUS INJURY OR DEATH. 

2.1.1

 

Only trained persons will be permitted to operate the Niftylift.

 

2.1.2

 

Always operate the Niftylift in full accordance with the manufacturers Operating & Safety Instructions 
for that model. 

2.1.3

 

Before use each day and at the beginning of each shift the Niftylift shall be given a visual inspection 
and functional test including, but not limited to, operating and emergency controls, safety devices, 
personal protective clothing, including fall protection, air, hydraulic and fuel system leaks, cables and 
wiring harness, loose or missing parts, tyres and wheels, placards, warnings, control markings and 
Operating and Safety Manuals, guards and guard rail systems and all other items specified by the 
manufacturer. 

2.1.4

 

Any problems or malfunctions that affect the safety of operations shall be repaired prior to the use of 
the Niftylift. 

2.1.5

 

Always ensure that all warning labels, instructions, placards, control markings and Safety Manuals are 
intact and clearly legible. If replacements are required  contact  your  local  dealer  or  Niftylift.    Always 
observe and obey safety and operating instructions on such labels. 

2.1.6

 

Do not alter, modify or disable in any way the controls, safety devices, interlocks or any other part of 
the machine. 

2.1.7

 

Before the Niftylift is used and during use the user shall check the area in which it is to be 
used for possible hazards such as, but not limited to, uneven ground drop-offs, holes, bumps, 
obstructions, debris, floor and overhead obstructions, high voltage conductors, wind and 
weather, unauthorised persons and any other possibly hazardous conditions. 

2.1.8

 

Never exceed the maximum platform capacity, as indicated on the decals and machine serial plate. 

2.1.9

 

Only operate the Niftylift on a firm, level surface. 

2.1.10

 

Never position any part of the Niftylift within 4.0m, (12ft) of any electrical power line, conductor or 
similar not exceeding 66kV. (Minimum span 125m)  Other distances for increased voltages and 
different spans are given in NZECP 34:1993. 

Содержание HR15

Страница 1: ...Operating Safety Instructions MODEL HR15 SP45 HR17 SP50 2x4 4x4 SERIES Manufactured by Niftylift Limited Fingle Drive Stonebridge Milton Keynes MK13 0ER England www niftylift com e mail info niftylif...

Страница 2: ......

Страница 3: ...es 12 13 3 4 Placard Decals and Installation 14 17 3 5 Torque Requirements 18 4 OPERATION 4 1 Control Circuit Components 19 20 4 2 Ground Control Operation 21 22 4 3 Platform Control Operation 23 24 4...

Страница 4: ...ipment is only as safe as those who operate it 1 2 SEVERITY OF HAZARDS The use of this type of equipment presents certain dangers to the operator which are clearly identified both in this manual and o...

Страница 5: ...ive Stonebridge Milton Keynes MK13 0ER Great Britain Tel 44 0 1908 223456 Fax 44 0 1908 312733 Niftylift Inc 32 Concourse Way Greer SC 29651 USA Tel 01 864 968 8881 Fax 01 864 968 8836 Nifty Pty Ltd 2...

Страница 6: ...WHEELBASE 1 8m 5ft 11in TURNING RADIUS OUTSIDE 4 05m 13ft 3in TURRET ROTATION 3550 TURRET TAIL SWING Zero TRAVEL SPEED 0 3 2mph 0 5 1kph 0 4 1mph 0 6 6kph 0 3 2mph 0 5 1kph 0 4 1mph 0 6 6kph PLATFORM...

Страница 7: ...TION UK PLATE 0 1 2 3 4533 3 3 63 45 1 33 45 333 1 333 78 1 0 333 5 2 0 33 9 3 333 3 333 0 00 3 2 00 33 This manufacturer s plate is attached to Boom 1 on each machine at the time of manufacture on ev...

Страница 8: ...A PLATE 0 1 2 3 2 1 0 4 3 4 3 2 3 5 55 2 0 0 555 1 0 555 4 0 4 3 2 4 55 2 4 5 555 5 2 555 3 33 5 4 0 33 55 4 2 This manufacturer s plate is attached to Boom 1 on each machine at the time of manufactur...

Страница 9: ...tion and functional test including but not limited to operating and emergency controls safety devices personal protective clothing including fall protection air hydraulic and fuel system leaks cables...

Страница 10: ...ftylift Ltd in Great Britain 2 1 17 Always check that the area below and around the platform is clear of personnel and obstructions before lowering or slewing Care should be taken when slewing out int...

Страница 11: ...flame sparks or other hazards which may cause explosion Highly explosive hydrogen gas is produced during the charging process 2 1 32 When checking electrolyte levels great care should be taken to prot...

Страница 12: ...ation excess oil or grease should be removed Deposits of paint or bitumen particularly on legends or labels should be removed All standard Niftylift machines are rated for a wind speed of 12 5 m s whi...

Страница 13: ...as read and fully understood this entire manual Refer to the appropriate section for precise operating instructions Carry out the Pre operational Report before placing machine in service 3 2 PREPARATI...

Страница 14: ...re secure and operate freely 8 Check that operating buttons and emergency stop buttons function properly 9 Check the operation of the emergency hand pump 10 Visually inspect all hydraulic hoses and fi...

Страница 15: ...the end cap on the main knuckle pin is secure and the roll pin is in place 10 Check and adjust if necessary the Nylatron studs around the telescope boom 11 Every three months check and verify the cali...

Страница 16: ...P14802 4 15 Battery Isolator P18600 1 16 No Step P14785 3 17 Logo Nifty HR15 Nifty HR17 P14606 P15166 2 2 18 Logo Height Rider 15 Height Rider 17 P14607 P15165 2 2 19 Trip Push to reset P19056 1 20 Fo...

Страница 17: ...2 46 Soft Stop Warning HR15 2x4 P17460 1 28 28 28 28 11 11 11 11 35 18 18 17 17 5 9 36 34 23 27 22 4 33 19 16 16 6 30 8 16 15 14 12 14 13 14 14 1 26 4 2 2 25 5 46 9 21 7 24 40 D80585 5 INSIDE COVER O...

Страница 18: ...Disengage P14802 4 15 Battery Isolator P18600 1 16 No Step P14785 3 17 Logo Nifty SP45 Nifty SP50 P14617 P19184 2 2 19 Trip Push to reset P19056 1 20 Footswitch P14884 1 21 Cage Control Levers P14020...

Страница 19: ...9725 1 43 Cage Overload Warning P18848 2 28 28 28 28 11 11 11 11 11 35 17 17 5 9 36 34 23 27 22 4 33 19 16 16 6 30 16 15 14 12 14 13 14 14 1 26 4 2 2 25 5 41 9 21 7 24 40 INSIDE COVER ON SIDE OF ELECT...

Страница 20: ...SCREW QUALITY SIZE Tightening torque in ft lbs Nm Grade 8 8 10 9 M 6 7 0 10 10 14 M 8 19 25 26 35 M 10 36 49 51 69 M 12 63 86 89 120 M 14 99 135 140 190 M 16 155 210 218 295 M 18 214 290 300 405 WHEEL...

Страница 21: ...rm Sensor detects excessive inclination with the booms raised Thirdly this will sound when the low fuel warning light comes on Lastly it is linked into the battery management system such that when low...

Страница 22: ...which allows the machine control and power circuits to be isolated from the batteries themselves Under normal operation the machine Key switch should be used to isolate the machine with the Battery pl...

Страница 23: ...or Booms 3 Diesel Glow Start Selector Turn Clockwise Glow Off and Start posistions Base Levers 1 2 3 4 5 6 1 Operates Platform Levelling Up for Backward Down for Forward 2 Operates the Flyboom Up for...

Страница 24: ...the base control box 6 Select a function and operate the appropriate hydraulic lever in full accordance with manufacturers operating and safety manual 7 To return control to the platform turn the Bas...

Страница 25: ...low Push to Glow Engine 6 Drive Speed Selector Turn Clockwise Slow Fast and Rough terrain modes 7 Green Power Button Push and hold to activate machine 8 On Off Diesel Start 9 Joystick Cage Levers 1 2...

Страница 26: ...osition clockwise and the engine will fire 7 WARM ENGINE turn the On Off Diesel Start selector to the Start position clockwise and the engine will fire ALL MODELS 8 Depress the footswitch if available...

Страница 27: ...separate horn button on the platform controls for use when the drive and boom controls are switched off 5 All control levers give a fully proportional response therefore the more the lever is moved a...

Страница 28: ...this facility especially if the machine is significantly overloaded any motion that causes the machine outreach to increase could induce instability The machine must be manoeuvred in such a manner as...

Страница 29: ...s securing it 3 With the spring mechanism relaxed the bottom cage bracket comes into contact with the cage support frame and will support the cage travel This also gives the system it s full over trav...

Страница 30: ...precision needle roller bearings for smooth running and friction free operation The accuracy of the entire assembly and in particular the hysteresis is dependent on these components Keeping them free...

Страница 31: ...ct travel within the switch itself Using a non equivalent component will render the cage weigh system inactive Under no circumstances should you permit a machine with a defective cage weigh assembly t...

Страница 32: ...Green light and pulsing Red light the batteries are fully charged UNDER NO CIRCUMSTANCES SHOULD BATTERIES BE LEFT ON CHARGE FOR PERIODS IN EXCESS OF 24 HOURS 4 DISCONNECT FROM POWER SUPPLY ONCE BATTER...

Страница 33: ...n lead to a reduction in the chargers efficiency Both of these can result in over heating of the cable with the attendant risk of fire short circuits or damage to the components themselves The charger...

Страница 34: ...to come into contact with other goods being shipped or the container itself Some movement of the machine structure might occur during transit which could lead to fretting or other damage If the machi...

Страница 35: ...event deterioration 4 7 4 SETTING TO WORK If your machine has arrived direct from the factory or via a dealer then it may safely be put straight to work However if the machine has been in storage or i...

Страница 36: ...around you are clear of the moving cage When the system has been charged in both directions the cage levelling function should be restored If the system operates but is jerky in either direction this...

Страница 37: ...s at ground control station Note If the machine is fitted with a cage overload system and the cage comes into contact with a fixed object whilst operating at height this would be detected as an overlo...

Страница 38: ...an hold the appropriate lever to manoeuvre the machine whilst a ground operative provides the motive power using the emergency hand pump When not in use the handle should be stowed back in its clips 5...

Страница 39: ...lease actuator whilst pumping the handle When brake pressure is generated the brake tell tale will indicate this by popping out of the housing The brakes are now bypassed and the machine is capable of...

Страница 40: ...ury or property was damaged is reported by telephone directly to Niftylift Failure to do so may render any warranty on the machine void 6 Responsibilities 6 1 CHANGES IN OWNERSHIP When a change of own...

Страница 41: ...Operation of all booms over full range Wheel bearings OK Cylinders are silent Platform is level over full range Booms levelling rods not damaged or distorted Booms levelling rods cylinders not foulin...

Страница 42: ...connections secure Hoses not kinked or fouled Charger control box secure Batteries secure Electrolyte level and specific gravity Charger operation Hydraulic oil level Engine Gear box oil FINISH Pivot...

Отзывы: