Service Manual
HR15/17N HYBRID DC
English 07/16
44
5.3
Boom System
The boom system uses a maximum of 25L/min from the pump. Functions can be operated proportionally
and simultaneously until the demand reaches 25L/min. If the demand exceeds 25L/min then the flow is
shared between the functions with priority given to the function with the lowest operating pressure.
DC Only Mode
The electric motor is set to run at 2200RPM during booms operation. Booms have full functionality in
electric only mode with no limitations with regard to speed or load.
Hybrid Mode
In Hybrid mode the engine is set to run at 1800 RPM in a no load condition. The engine can be loaded
either by battery charging or by operating the booms. If the revs drops below 1700 RPM, battery charging
stops temporarily and the engine then supplies full power to lift the booms, if it drops further then the
electric motor will support the shaft to keep the revs above 1700 RPM. Once load is taken off the engine,
revs will recover above 1700 RPM and charging will start automatically. Charging current constantly
varies depending on the excess power available.
If the electric system fails to function (controller failure, motor failure, etc) the booms can be operated in
diesel only mode. However, this mode is only for low duty functions and for assisting to recover the
booms back to the transport position. Full boom function performance is only available in electric only or
hybrid modes.
5.4
Drive System
5.4.1
Hybrid
The drive system uses 60L/min maximum flow from the pump. The table below describes the available
driving modes.
Electric Only Mode
All the listed driving modes are available in electric only operation. Available power is reduced to 8kW and
hence performance is reduced. It is advisable to switch to hybrid mode when high power demand is
required e.g. off road driving.
Hybrid Mode
In hybrid mode a full 23kW of combined power is available for machine functions. In this mode the
machine consumes battery power to support the engine when required and regenerates battery power
when the function duty is low. Under continued high duty function for long periods the battery levels will
be significantly reduced to support the high power requirement. Under such conditions it will be normal
to have to recharge the battery levels prior to electric only use.
Driving Mode
Speed HR15N
Speed HR17N
Gradeablity %
Hare
3.3 km/h (2.1 mph)
3.6 km/h (2.2 mph)
20
Tortoise
1.0 km/h (0.6 mph)
1.2 km/h (0.7 mph)
20
Off road
1.2 km/h (0.7 mph)
1.3 km/h (0.8 mph)
45