Nielsen CT2141 Скачать руководство пользователя страница 1

 1 

 

 10 

 

 
 
 

Gas Forced Heater/ LPG 50KW  CT2141 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 

 

ORIGINAL INSTRUCTIONS 

Cannon Tools Limited 

Address:20 Station Road, Rowley Regis, West Midlands, B65 0JU.UNITED KINGDOM 

 

SAVE THESE INSTRUCTI

ON

S AND PRECAUTIONS. 

READ ALL PRECAUTONS AND INSTRUCTIONS BEFORE USE. 

CIRCUIT DIAGRAM 

 
 
 
 

 
 
 
 
 
 
 
 
 

HEATER SPECIFICATIONS 

Содержание CT2141

Страница 1: ...RIGINAL INSTRUCTIONS Cannon Tools Limited Address 20 Station Road Rowley Regis West Midlands B65 0JU UNITED KINGDOM SAVE THESE INSTRUCTIONS AND PRECAUTIONS READ ALL PRECAUTONS AND INSTRUCTIONS BEFORE...

Страница 2: ...w Voltage Directive 2014 35 EU EC Directive of Electromagnetic Compatibility 2014 30 EU Harmonized standards EN 55014 1 2006 A1 2009 A2 EN 55014 2 1997 A1 2001 A2 EN 61000 3 2 EN 61000 3 3 EN 60335 2...

Страница 3: ...bove and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe w...

Страница 4: ...ards the cylinder 1 5 Use only the supplied pressure regulator 1 6 Never use the heater without its cover 1 7 Do not exceed 100W m of free room The minimum volume of the room must be larger than 100m...

Страница 5: ...pletely Do not produce sparks or free flames 1 19 If in any doubt contact your supplier 2 INSTALLATION 2 1 Connect the heater to a suitable electric socket 230V 50Hz 2 2 Make sure that the machine is...

Страница 6: ...If ignition is difficult or irregular before repeating the ignition operations make sure that the fan is not locked and the air inlet and outlet are unobstructed 3 2 SWITCH OFF To stop the heater shut...

Страница 7: ...ect a propane leak keep out of all low areas 5 Use your neighbor s phone and call your fuel gas supplier and your fire department Do not reenter the building or area 6 Stay out of the building and awa...

Страница 8: ...and clean it The solenoid gas valve is not open Check that the solenoid valve works There is no spark Check the position of electrode The burner lights up but after few seconds the heater stops No co...

Страница 9: ...e control no At minimum heat output elmin N A kW Two or more manual stages no room temperature control yes In standby mode elSB N A kW with mechanic thermostat room temperature control no with electro...

Страница 10: ...cy in active mode S on 100 Correction factor F1 0 Correction factor F2 0 Correction factor F3 0 Correction factor F4 0 Correction factor F5 0 Biomass label factor BLF 1 The seasonal space heating ener...