No power to broiler when the switch is turned on.
Check: Broiler is plugged in.
Circuit Breaker on wall panel is on.
Broiler has power, but the burners do not light.
Check: Ventilation hood is on.
Gas line is properly plugged in.
Manual gas valve (if equipped) is on.
Burners are installed properly.
Burners are clean and dry.
Flame sensor wire connection.
Follow manual lighting instructions.
Red light blinking on left control box.
Check the items above for burners not lighting.
Turn power off and on again to reset ignition.
Follow manual lighting instructions.
Hot surface ignitor does not heat.
Check for loose wires connecting the hot surface ignitor.
Follow manual lighting instructions.
Power is on, broiler is lit, but the conveyor belts are not
turning.
Check for a jam in the conveyor belt. Use the belt reverse
buttons located on the side of the control box to help clear
a belt jam. Check the stripper blade to make sure it is
installed properly.
Feeder belt not moving.
Make sure the feeder is assembled properly.
Check for jam.
Make sure the drive pin is engaged.
Burgers sticking to slide or stripper blade.
Clean the slide and stripper blade very thoroughly.
Check cookout temperature (undercooking).
Burgers under or over cooked.
Adjust conveyor belt speed.
Clean burners and orifices.
Excessive flaming in broiler.
Clean the catalyst if equipped.
Check the hood for proper operation.
Check product for overcooking.
E. TROUBLESHOOTING
24
Nieco Corporation - Model MPB73
Always verify that the broiler is properly assembled, the hood is on, gas valve open and broiler is plugged in.
Replace the following parts according to this schedule or as needed:
Problem:
Possible Solution:
Recommended Maintenance
Yearly
Replace: P/N
2185
Zip Tube Orifice
P/N
2182
Pilot Orifice
Every 6 Months
Replace: P/N
17185
Flame Sensor