274
APPENDIX: Standard Programs
Programs C to E: Empty
Program
: Day/Night measurement course
(Day/Night measurement course) is a course performing night measurement after the day mea-
surement.
The Day course is a course to achieve the best possible visual acuity with the most plus power based
on the objective measurement data. The Night course is a course to achieve the best possible visual
acuity with the most plus power for night vision based on the full correction value for daytime vision.
It is necessary to enter the objective and subjective (copied from the objective) data with an auto
refractometer before Program
.
<For Day>
1. R: AR data check
Check that the VA is about 20/30 in the AR data.
2. R: Red-green test
Spherical refinement with the red-green chart (fog + 0.5)
3. R: Cross cylinder test (axis)
Measure the cylindrical axis with the cross cylinder lens.
4. R: Cross cylinder test (power)
Measure the cylindrical power with the cross cylinder lens.
5. R: Red-green test
Spherical refinement with the red-green chart (fog + 0.5)
6. R: Best possible VA check (monocular full correction)
Best possible VA on the chart with the most plus power
7. L: AR data check
Check that the VA is about 20/30 in the AR data.
8. L: Red-green test
Spherical refinement with the red-green chart (fog + 0.5)
9. L: Cross cylinder test (axis)
Measure the cylindrical axis with the cross cylinder lens.
10. L: Cross cylinder test (power)
Measure the cylindrical power with the cross cylinder lens.
11. L: Red-green test
Spherical refinement with the red-green chart (fog + 0.5)
12. L: Best possible VA check (monocular full correction)
Best possible VA on the chart with the most plus power
13. B: Binocular balance test
Test the binocular balance.
14. B: Stereo test
Check of stereophonic vision and input of stereoparallax
15. B: Best possible VA check Power adjustment
Best possible VA on the chart with the most plus power
16. B: Addition power measurement
Measure the addition power with the cross grid chart for near point
17. B: Addition power check
Measure the VA in the addition power with the near VA chart
<For Night>
18. R: VA measurement using day data in Night mode
Measure the VA with the day data in night brightness
19. R: Red-green test
Spherical refinement with the red-green chart (fog + 0.5)
20. R: Cross cylinder test (axis)
Measure the cylindrical axis with the cross cylinder lens.
161221687130 承認済
Uncontrolled copy when printed.
Содержание RT-5100
Страница 12: ...X 161221687130 承認済 Uncontrolled copy when printed ...
Страница 18: ... XVI 161221687130 承認済 Uncontrolled copy when printed ...
Страница 46: ...28 BEFORE USE Getting Started and Exiting 161221687130 承認済 Uncontrolled copy when printed ...
Страница 226: ...208 TEST METHOD Visual Acuity Test by ETDRS chart 161221687130 承認済 Uncontrolled copy when printed ...
Страница 274: ...256 MAINTENANCE List of Replacement Parts 161221687130 承認済 Uncontrolled copy when printed ...
Страница 302: ...284 EMC ELECTROMAGNETIC COMPATIBILITY 161221687130 承認済 Uncontrolled copy when printed ...