USER'S GUIDE

Mark 5 Nuvo

(OCSI)

Lite

OXYGEN CONCENTRATOR

Federal Law (US) restricts this device to sale
or use by, or on the order of, a licensed phy-
sician. This oxygen concentrator should be
used only under the supervision of a licensed
physician.

0413

Complies with the 93/42/EEC directive

certifi ed by the approved organization no 0413.

Contents

: ON (power switched on)

: OFF (power switched off)

: Type B device

: Class II protection

:  Do not expose to open fl ames

: Do not use oil or grease

: Technical information

: Consult the accompanying documents

: Keep in the vertical position

: Fragile - handle with care

: Oxygen concentration warning light

GLOSSARY OF SYMBOLS

[Original language is English]

GLOSSARY OF SYMBOLS..........................................

1

GENERAL SAFETY GUIDELINES ............................

2

1

Unpacking and Packaging.......................................

3

1.1

Method for disposing of waste..................................3

1.2

Method for disposing of device.................................3

2

DESCRIPTION.......................................................

3

2.1

Front panel (Fig. 2.1)......................................... 4

2.2

Rear panel (Fig. 2.2) ..............................................4

3

STARTING-UP / INSTALLATION

.......................4

3.1

Use in direct oxygen therapy ...................................4

3.2

Turning off device.....................................................5

4

CLEANING-MAINTENANCE ...............................

5

4.1

Cleaning ...................................................................5

4.2

Daily disinfection..........................................................5

4.3

Maintenance............................................................ 6

5

USEFUL INFORMATION........................................

6

5.1

Accessories and spare parts....................................... 6

5.2

Material in direct or indirect contact with patient..... 7

5.3

Operating principles.................................................. 7

5.4

Alarms-Safety devices-Indications ........................... 7

5.5

OCSI function .......................................................... 8

5.6

Technical characteristics ........................................... 8

5.7

Standards................................................................... 9

5.8

Troubleshooting.......................................................10

Notes.................................................................................

11

Danger: Do not smoke when using oxygen or when
near this device.

I

O

Содержание Mark 5 Nuvo OCSI Lite 3

Страница 1: ...gen concentration warning light GLOSSARY OF SYMBOLS Original language is English GLOSSARY OF SYMBOLS 1 GENERAL SAFETY GUIDELINES 2 1 Unpacking and Packaging 3 1 1 Method for disposing of waste 3 1 2 M...

Страница 2: ...ing to quali ed service personnel GENERAL SAFETY GUIDELINES Only persons who have read and understood this entire manual should be allowed to operate the MARK 5 Nuvo Lite TheCAUTIONSbelowindicateapote...

Страница 3: ...detected please contact your equipment provider Operating environmental condi tion guidelines are discussed later in another section of this User s Guide 1 1 METHOD FOR WASTE DISPOSAL All waste from t...

Страница 4: ...r the humidi er bottle manufacturer s recommendation Re attach the lid to the bottle and connect to the oxygen concentrator Place the bottle on the concentrator and secure with the attachment straps a...

Страница 5: ...Adjust the nasal cannula to suit your face see Fig 3 4 1 Filter Silencer 2 Cabinet lter 3 Ventilation grill Note Shown with grate removed 115V Fig 3 3 230V Fig 4 1 3 2 Turning off device Attheendofth...

Страница 6: ...cuit oxygentherapynasalcannula etc must be changed 4 3 Maintenance No special maintenance needs to be carried out by the patient Your equipment supplier performs periodic maintenance operations to ass...

Страница 7: ...rms No voltage detection In the event of a loss of mains power an inter mittent audible alarm is activated and the green light turns off Test alarm by actuating the I O ON OFF switch when the power co...

Страница 8: ...he OCSI function In compliance with the ISO 8359 standard The ow supplied is equal to the selected ow accurate to within 10 or 200 ml min whichever is the larger Oxygen Concentration at 2 l min 90 at...

Страница 9: ...repairable Electrical power supply Rating 230V 50Hz Average Power 180 W avg Protection Class Class II Mains Protection 5A Filters At the rear of the device a cabinet air lter At the compressor input a...

Страница 10: ...blockage Fan is not working Tube disconnected or humidi er cap is not tight Cannula tubing is restricted Observations The I O ON OFF button is in the I ON position but the device does not operate The...

Страница 11: ...__________________ ___________________________________________________________________ ___________________________________________________________________ _____________________________________________...

Страница 12: ...Drive Birmingham Alabama 35217 U S A Tel 205 856 7200 Fax 205 856 0533 info nidekmedical com www nidekmedical com EU Representative mdi Europa GmbH Langenhagener Str 71 30855 Hannover Langenhagen Ger...

Отзывы: