Nidec Shimpo ST-320BL Скачать руководство пользователя страница 3

LCD Display

Main Data Display

•Flash rate value will be displayed in internal flashing or Exter-
nal trigger mode.

•Display will indicate “P” or “LCD” (in ON/OFF setting of LCD 
backlight) in *Parameter setting mode.

*For details about Parameter setting mode, please refer to Pa-
rameter setting mode.

Sub Data Display

Internal Mode
•Phase Shift will indicate degrees of phase shift in internal flash-
ing mode. To change the degrees of phase shift, press + or - 
keys. The display will reflect the cumulative angle of phase shift.

•The flash duration time will be displayed when the RATIO key 
is pressed. The flash duration time can then be increased or 
decreased with the dial from 0 to 2.5 (0~2.5°) degrees.

External Mode
• In external trigger mode, the display will show the settings of 
delay time. For details about changing these settings, please 
see external trigger mode section.

FUNCTION INSTRUCTIONS

Mode Selection - To switch between INTERNAL, EXTERNAL and 
PARAMETER menu, press and release the MODE key. For details 
about Parameter setting mode, please refer to Parameter setting 
menu section.

Internal Flashing Mode

Changing Units of Measure in Internal Mode - To change the 
measuring units from FPM to Hz, press and release the SET key.
Units will alternate with each press and release.

Flash Rate (Frequency Setting) in Internal Mode 
You can set the flash rate by turning the dial in the center of the 
unit. To increase the flash rate, turn the dial in the clockwise direc-
tion. To decrease the flash rate, turn the dial in the counter-clock-
wise direction. For small adjustments, turn the dial slowly. For 
quick adjustments, rotate the dial quickly. The flash rate range 
and resolution will be different according to the selected measur-
ing range. 

One function of a stroboscope is to provide a “stopped” image 
of a rotating target when the flash rate of the stroboscope has 
matched the rotational speed of the target object. The strobo-
scope will show a single image when the flash rate is set to a 
lesser multiple of the true RPM (1/2,1/3,etc.) When the flash rate 
is increased to a higher multiple (2,3,etc.), multiple images will 
appear. To find the true RPM of the target object, reduce the flash 
rate to a lower multiple until only one image appears. 

2

Parameter
Icons

Sub
Data Display

Main

Data

Display

Units

Содержание Shimpo ST-320BL

Страница 1: ...ustin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and mea...

Страница 2: ...ly 3 5 years depending on usage Display Backlit LCD Resolution 60 12 000 FPM 0 1 FPM 12 001 120 000 FPM 1 FPM 1 200 HZ 0 01 Hz 201 2000 0 1 Hz Flash Duration 0 1 2 5 Phase Shift 0 359 Power Requiremen...

Страница 3: ...Parameter setting menu section Internal Flashing Mode Changing Units of Measure in Internal Mode To change the measuring units from FPM to Hz press and release the SET key Units will alternate with e...

Страница 4: ...he x2 key Phase Shift Angle First press SET key then enter this mode When the rotation speed of the target object and the flash rate of the ST 320BL becomes equal the phase shift function can be used...

Страница 5: ...nters EXTER 1 In this mode frequency HZ or speed FPM automatically flash according to the external trigger signal After setting the parameters generally the detected object has an advanced or lag phen...

Страница 6: ...ll go to 0 as the angle increases past 359 Delay angle decreases as the dial is rotated to the left The set tings will eventually go to 0 as the angle decreases past 359 Parameter Settings To enter pa...

Страница 7: ...n using battery power Flashing will resume with either a dial rotation movement or a keypad operation The LED auto shutoff will not occur in External trigger mode while a signal is being received by t...

Отзывы: